Conventional diagnosis of Treponema pallidum in serum using latex piezoelectric immunoassay

被引:11
作者
Aizawa, H
Kurosawa, S
Tanaka, M
Wakida, S
Talib, ZA
Park, JW
Yoshimoto, M
Muratsugu, M
Hilborn, J
Miyake, J
Tanaka, H
机构
[1] Natl Inst Adv Ind Sci & Technol, AIST, Natl Inst Mat & Chem Res, Dept Organ Mat, Tsukuba, Ibaraki 3058565, Japan
[2] Natl Inst Adv Ind Sci & Technol, AIST, Natl Inst Adv Interdisciplinary Res, Tsukuba, Ibaraki 3058563, Japan
[3] Univ Tsukuba, Tsukuba, Ibaraki 3058572, Japan
[4] Natl Inst Adv Ind Sci & Technol, AIST, Natl Inst Biosci & Human Technol, Tsukuba, Ibaraki 3058566, Japan
[5] Natl Inst Adv Ind Sci & Technol, AIST, Osaka Natl Res Inst, Ikeda, Osaka 5638577, Japan
[6] Kagoshima Univ, Kagoshima 8900065, Japan
[7] Osaka Prefectural Coll Publ Hlth, Osaka 5838555, Japan
[8] Swiss Fed Inst Technol, DMX LP, CH-1015 Lausanne, Switzerland
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2001年 / 17卷 / 1-2期
关键词
immunosensor; quartz crystal microbalance; Treponema pallidum; Syphilis; screening;
D O I
10.1016/S0928-4931(01)00320-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We developed a conventional immunosensor for Treponema pallidum (TP) to combine quartz crystal microbalance (QCM) with the agglutination reaction of immunized latex beads, TP induced an immunoreaction due to treponemal antigen-immobilized latex particles. We succeeded in measuring the concentration of TP in the human serum within 10 min by QCM method. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 26 条
[1]   Conventional diagnosis of C-reactive protein in serum using latex piezoelectric immunoassay [J].
Aizawa, H ;
Kurosawa, S ;
Ogawa, K ;
Yoshimoto, M ;
Miyake, J ;
Tanaka, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :173-176
[2]   Rapid diagnosis of Treponema pallidum in serum using latex piezoelectric immunoassay [J].
Aizawa, H ;
Kurosawa, S ;
Tanaka, M ;
Yoshimoto, M ;
Miyake, J ;
Tanaka, H .
ANALYTICA CHIMICA ACTA, 2001, 437 (02) :167-169
[3]   Syphilis testing [J].
Clyne, B ;
Jerrard, DA .
JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (03) :361-367
[4]   AMPLIFIED MASS IMMUNOSORBENT-ASSAY WITH A QUARTZ CRYSTAL MICROBALANCE [J].
EBERSOLE, RC ;
WARD, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (26) :8623-8628
[5]   LATEX PIEZOELECTRIC IMMUNOASSAY - EFFECT OF INTERFACIAL PROPERTIES [J].
GHOURCHIAN, HO ;
KAMO, N .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :99-105
[6]   IMPROVEMENT OF ALTEX PIEZOELECTRIC IMMUNOASSAY - DETECTION OF RHEUMATOID-FACTOR [J].
GHOURCHIAN, HO ;
KAMO, N ;
HOSOKAWA, T ;
AKITAYA, T .
TALANTA, 1994, 41 (03) :401-406
[7]  
Ghourchian HO, 1998, RRD PURE APPL ANALYT, V1, P9
[8]  
KUROSAWA S, 1990, CHEM PHARM BULL, V38, P1117
[9]   Latex piezoelectric immunoassay: Analysis of C-reactive protein in human serum [J].
Kurosawa, S ;
Aizawa, H ;
Yoshimoto, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (05) :1256-1258
[10]   OSCILLATING FREQUENCY OF PIEZOELECTRIC QUARTZ CRYSTAL IN SOLUTIONS [J].
KUROSAWA, S ;
TAWARA, E ;
KAMO, N ;
KOBATAKE, Y .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :41-49