Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studies

被引:101
作者
Schurink, GWH
Aarts, NJM
van Bockel, JH
机构
[1] Leiden Univ, Med Ctr, Dept Surg, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
关键词
D O I
10.1046/j.1365-2168.1999.01119.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endoleak is the major complication after endovascular treatment of abdominal aortic aneurysm (AAA) and its incidence seems to remain significant. Little is known about the association of device type and configuration with respect to the incidence, location, time of onset and fate of endoleakage. Methods: A meta-analysis was performed via a Medline search of clinical studies after 1995 dealing with the endovascular treatment of AAA. Details of number of patients treated, configuration and type of endovascular device were collected. Data concerning site of origin, time of occurrence and fate of the endoleak were retrieved, along with information on change in diameter of the aneurysm with time. Results: The 23 publications included reported on 1189 patients. The 1118 patients with successfully inserted transfemoral endovascular grafts experienced 270 endoleaks (24 per cent). The majority arose from the distal stent attachment site (36 per cent), were present immediately after stent-graft placement (66 per cent) and were persistent in time (37 per cent). Tube grafts were more frequently affected by endoleakage (35 per cent; P < 0.0001), especially at the distal stent attachment site (51 per cent), than bifurcated grafts (18 per cent; P = 0.004) and aortounilateral devices (20 per cent; P = 0.70). Self-expandable stent-grafts were more frequently associated with endoleaks (25 per cent) than balloon-expandable stent-grafts (17 per cent) (P = 0.037). Conclusion: Endovascular treatment of AAA is an evolving held. Even after the initial learning curve and attention to device-related problems, it is still accompanied by a significant number of endoleaks. Uniform presentation of results of treatment is necessary for analysing the effect of differences between patients, aneurysm morphology and device type.
引用
收藏
页码:581 / 587
页数:7
相关论文
共 51 条
[1]  
Adiseshiah M, 1997, J ENDOVASC SURG, V4, P286, DOI 10.1583/1074-6218(1997)004<0286:EROLAA>2.0.CO
[2]  
2
[3]   Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair [J].
Ahn, SS ;
Rutherford, RB ;
Johnston, KW ;
May, J ;
Veith, FJ ;
Baker, JD ;
Ernst, CB ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) :405-410
[4]   Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction [J].
Alimi, YS ;
Chakfe, N ;
Rivoal, E ;
Slimane, KK ;
Valerio, N ;
Riepe, G ;
Kretz, JG ;
Juhan, C .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) :178-183
[5]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[6]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[7]   The efficacy of transfemoral endovascular aneurysm management: A study on size changes of the abdominal aorta during mid-term follow-up [J].
Broeders, IAMJ ;
Blankensteijn, JD ;
Gvakharia, A ;
May, J ;
Bell, PRF ;
Swedenborg, J ;
Collin, J ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (02) :84-90
[8]  
BROWN MMD, 1996, CARDIOVASCULAR SURG, V4, P706
[9]  
Chuter T A, 1997, Cardiovasc Surg, V5, P388, DOI 10.1016/S0967-2109(97)00036-7
[10]  
Cuypers P, 1997, Ned Tijdschr Geneeskd, V141, P1385