The right information may matter more than frequency-place alignment: Simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion

被引:35
作者
Faulkner, A [1 ]
Rosen, S [1 ]
Norman, C [1 ]
机构
[1] UCL, Dept Phonet & Lingust, London NW1 2HE, England
基金
英国惠康基金;
关键词
D O I
10.1097/01.aud.0000202357.40662.85
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: It has been claimed that speech recognition with a cochlear implant is dependent on the correct frequency alignment of analysis bands in the speech processor with characteristic frequencies (CFs) at electrode locations. However, the use of filters aligned in frequency to a relatively basal electrode array position leads to significant loss of lower frequency speech information. This study uses an acoustic simulation to compare two approaches to the matching of speech processor filters to an electrode array having a relatively shallow depth within the typical range, such that the most apical element is at a CF of 1851 Hz. Two noise-excited vocoder speech processors are compared, one with CF-matched filters, and one with filters matched to CFs at basilar membrane locations 6 mm more apical than electrode locations. Design: An extended crossover training design examined pre- and post-training performance in the identification of vowels and words in sentences for both processors. Subjects received about 3 hours of training with each processor in turn. Results: Training improved performance with both processors, but training effects were greater for the shifted processor. For a male talker, the shifted processor led to higher post-training scores than the frequency-aligned processor with both vowels and sentences. For a female talker, post-training vowel scores did not differ significantly between processors, whereas sentence scores were higher with the frequency-aligned processor. Conclusions: Even for a shallow electrode insertion, we conclude that a speech processor should represent information from important frequency regions below 1 kHz and that the possible cost of frequency misalignment can be significantly reduced with listening experience.
引用
收藏
页码:139 / 152
页数:14
相关论文
共 30 条
[1]  
*ANSI, 1997, S351997R2002 ANSI
[2]   Lexical information drives; Perceptual learning of distorted speech: Evidence from the comprehension of noise-vocoded sentences [J].
Davis, MH ;
Johnsrude, IS ;
Hervais-Adelman, A ;
Taylor, K ;
McGettigan, C .
JOURNAL OF EXPERIMENTAL PSYCHOLOGY-GENERAL, 2005, 134 (02) :222-241
[3]   METHOD FOR TRAINING AND EVALUATING RECEPTION OF ONGOING SPEECH [J].
DEFILIPPO, CL ;
SCOTT, BL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (04) :1186-1192
[4]   Simulating the effect of cochlear-implant electrode insertion depth on speech understanding [J].
Dorman, MF ;
Loizou, PC ;
Rainey, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05) :2993-2996
[5]   Speech understanding by cochlear-implant patients with different left- and right-ear electrode arrays [J].
Dorman, MF ;
Dahlstrom, L .
EAR AND HEARING, 2004, 25 (02) :191-194
[6]   Adaptation by a cochlear-implant patient to upward shifts in the frequency representation of speech [J].
Dorman, MF ;
Ketten, D .
EAR AND HEARING, 2003, 24 (05) :457-460
[7]   Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth [J].
Faulkner, A ;
Rosen, S ;
Stanton, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (02) :1073-1080
[8]   Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor [J].
Fishman, KE ;
Shannon, RV ;
Slattery, WH .
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1997, 40 (05) :1201-1215
[9]  
FLETCHER H, 1930, J ACOUST SOC AM, V1, P1
[10]   LIP-READING THE BKB SENTENCE LISTS - CORRECTIONS FOR LIST AND PRACTICE EFFECTS [J].
FOSTER, JR ;
SUMMERFIELD, AQ ;
MARSHALL, DH ;
PALMER, L ;
BALL, V ;
ROSEN, S .
BRITISH JOURNAL OF AUDIOLOGY, 1993, 27 (04) :233-246