Influence of guiding catheter selection on the measurement of coronary flow reserve

被引:6
作者
Abizaid, A [1 ]
Kornowski, R [1 ]
Mintz, GS [1 ]
Hong, MK [1 ]
Picahrd, AD [1 ]
Kent, KM [1 ]
Satler, LF [1 ]
Popma, JJ [1 ]
Bramwell, O [1 ]
Leon, MB [1 ]
机构
[1] WASHINGTON CARDIOL CTR,WASHINGTON,DC 20010
关键词
D O I
10.1016/S0002-9149(96)00850-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The impact of guiding catheter selection on the measurement of coronary flow reserve was assessed by injecting increasing doses of adenosine through 3 different catheters often used during coronary interventions. When guiding catheters with side holes were used, an approximate doubling of the adenosine dose was required to produce a coronary flow reserve response similar to a 12-μg dose of adenosine injected through guiding catheters without side holes.
引用
收藏
页码:703 / 704
页数:2
相关论文
共 7 条
[1]   CORONARY-ARTERY FLOW MONITORING FOLLOWING CORONARY INTERVENTIONS [J].
ANDERSON, HV ;
KIRKEEIDE, RL ;
STUART, Y ;
SMALLING, RW ;
HEIBIG, J ;
WILLERSON, JT .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (14) :D62-D69
[2]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[3]   Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients [J].
Donohue, Thomas J. ;
Kern, Morton J. ;
Aguirre, Frank V. ;
Bach, Richard G. ;
Wolford, Thomas ;
Bell, Calvin A. ;
Segal, Jerome .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :449-458
[4]   CLINICAL-APPLICATIONS OF THE DOPPLER CORONARY FLOW VELOCITY GUIDEWIRE FOR INTERVENTIONAL PROCEDURES [J].
KERN, MJ ;
DONOHUE, TJ ;
BACH, RG ;
CARACCIOLO, EA ;
FLYNN, MS ;
AGUIRRE, FV .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1993, 6 (04) :345-363
[5]   ALTERATIONS OF PHASIC CORONARY-ARTERY FLOW VELOCITY IN HUMANS DURING PERCUTANEOUS CORONARY ANGIOPLASTY [J].
SEGAL, J ;
KERN, MJ ;
SCOTT, NA ;
KING, SB ;
DOUCETTE, JW ;
HEUSER, RR ;
OFILI, E ;
SIEGEL, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :276-286
[6]   INTRACORONARY PRESSURE AND FLOW VELOCITY WITH SENSOR-TIP GUIDEWIRES - A NEW METHODOLOGIC APPROACH FOR ASSESSMENT OF CORONARY HEMODYNAMICS BEFORE AND AFTER CORONARY INTERVENTIONS [J].
SERRUYS, PW ;
DIMARIO, C ;
MENEVEAU, N ;
DEJAEGERE, P ;
STRIKWERDA, S ;
DEFEYTER, PJ ;
EMANUELSSON, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (14) :D41-D53
[7]   INTEROBSERVER VARIABILITY IN CORONARY ANGIOGRAPHY [J].
ZIR, LM ;
MILLER, SW ;
DINSMORE, RE ;
GILBERT, JP ;
HARTHORNE, JW .
CIRCULATION, 1976, 53 (04) :627-632