Are stentless valves hemodynamically superior to stented valves? A prospective randomized trial

被引:89
作者
Cohen, G
Christakis, GT
Joyner, CD
Morgan, CD
Tamariz, M
Hanayama, N
Mallidi, H
Szalai, JP
Katic, M
Rao, V
Fremes, SE
Goldman, BS
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Div Cardiovasc Surg, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
D O I
10.1016/S0003-4975(01)03338-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Although stentless aortic bioprostheses are believed to offer improved outcomes, hemodynamic benefits remain unsubstantiated. Methods. Fifty-three patients were randomized to receive the stented C-E pericardial valve (CE) and 46 patients the Toronto Stentless Porcine valve (SPV). Annuli were sized for the optimal insertion of both valve types, such that surgeons were required to commit to specific valve sizes before randomization. Echocardiographic measurements and functional status (Duke Activity Status Index) were assessed at 3 and 12 months postoperatively. Results. Although cardiopulmonary bypass times (CE: 118.6 +/- 36.3 minutes; SPV: 148.5 +/- 30.9 minutes; p = 0.0001) and aortic cross-clamp times (CE: 95.4 +/- 28.6 minutes; SPV: 123.6 +/- 24.1 minutes; p = 0.0001) were significantly prolonged in the SPV group, perioperative morbidity and mortality was similar between groups. Neither valve offered a superior internal diameter for any given annular diameter (mean decrease in left ventricular outflow tract diameter after valvular implantation: SPV: 3.4 +/- 1.11 mm versus CE: 3.7 +/- 1.33 mm; p = 0.25). Although labeled mean valve size was significantly larger in the SPV group, the actual mean valve size based on internal valvular diameter was no different between groups (CE: 21.9 +/- 2.0 mm; SPV: 22.3 +/- 2.0 mm; p = 0.286). Although effective orifice areas increased, and mean and peak transvalvular gradients decreased in both groups over time, no differences were demonstrated between groups at 12 months. Similarly, although significant regression of left ventricular mass was accomplished in both groups over time, no differences were demonstrated between groups. Finally, Duke Activity Status Index scores of functional status improved in both groups over time; however, no differences were noted between groups at 12 months postoperatively. Conclusions. Although offering excellent outcomes, stentless valves did not demonstrate superior hemodynamic indices in comparison to stented valves up to 12 months after implantation. (C) 2002 by The Society of Thoracic Surgeons.
引用
收藏
页码:767 / 775
页数:9
相关论文
共 34 条
[1]   Hemodynamics and left ventricular mass regression following implantation of the Toronto SPV stentless porcine valve [J].
Bach, DS ;
David, T ;
Yacoub, M ;
Pepper, J ;
Goldman, B ;
Wood, J ;
Verrier, F ;
Petracek, M ;
Aldrete, V ;
Rosenbloom, M ;
Azar, H ;
Rakowski, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10) :1214-1219
[2]   ASYMPTOMATIC VENTRICULAR ARRHYTHMIAS AND MORTALITY RISK IN SUBJECTS WITH LEFT-VENTRICULAR HYPERTROPHY [J].
BIKKINA, M ;
LARSON, MG ;
LEVY, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1111-1116
[3]  
CHAN KL, 1995, CAN J CARDIOL, V11, P391
[4]   Inaccurate and misleading valve sizing: A proposed standard for valve size nomenclature [J].
Christakis, GT ;
Buth, KJ ;
Goldman, BS ;
Fremes, SE ;
Rao, V ;
Cohen, G ;
Borger, MA ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1998, 66 (04) :1198-1203
[5]  
Cohen G, 1997, CIRCULATION, V96, P76
[6]   THE LONG-TERM RESULTS OF AORTIC-VALVE REPLACEMENT [J].
COHN, LH .
CHEST, 1984, 85 (03) :387-396
[7]   LEFT-VENTRICULAR HYPERTROPHY IS ASSOCIATED WITH WORSE SURVIVAL INDEPENDENT OF VENTRICULAR-FUNCTION AND NUMBER OF CORONARY-ARTERIES SEVERELY NARROWED [J].
COOPER, RS ;
SIMMONS, BE ;
CASTANER, A ;
SANTHANAM, V ;
GHALI, J ;
MAR, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (07) :441-445
[8]  
CZER LSC, 1990, J THORAC CARDIOV SUR, V100, P44
[9]   The Toronto SPV bioprosthesis: Clinical and hemodynamic results at 6 years [J].
David, TE .
ANNALS OF THORACIC SURGERY, 1999, 68 (03) :S9-S13
[10]  
DAVID TE, 1990, J THORAC CARDIOV SUR, V99, P113