Development of up-converting phosphor technology-based lateral-flow assay for rapidly quantitative detection of hepatitis B surface antibody

被引:63
作者
Li, Luping [1 ,2 ]
Zhou, Lei [3 ]
Yu, Yang [2 ]
Zhu, Ziwen [3 ]
Lin, Changqing [4 ]
Lu, Changlong [1 ]
Yang, Ruifu [3 ]
机构
[1] China Med Univ, Dept Immunol, Shenyang 110001, Peoples R China
[2] Shenyang Hosp Infect Dis, Shenyang 110006, Peoples R China
[3] Beijing Inst Microbiol & Epidemiol, Lab Analyt Microbiol, State Key Lab Pathogen & Biosecur, Beijing 100071, Peoples R China
[4] Beijing Hotgen Biotechnol Co Ltd, Beijing 100071, Peoples R China
关键词
Up-converting phosphor technology; Biosensor; Lateral-flow strip; Hepatitis B surface antibody; Clinical quantitative detection; CHRONIC-RENAL-FAILURE; HEALTH-CARE WORKERS; VIRUS-INFECTION; C VIRUS; VACCINE; IMMUNOGENICITY; ANTIGEN; IMMUNOASSAY; REPORTERS; CHILDREN;
D O I
10.1016/j.diagmicrobio.2008.10.020
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
An up-converting phosphor technology-based lateral-flow (UPT-LF) assay system was developed for rapid and quantitative detection of hepatitis B surface antibody (HBsAb). To evaluate its performance, we compared it with the Abbott Axsym AUSAB (ABBOTT Diagnostics Division, Wiesbaden, Germany) assay and conventional ELISA (Wantai Biological Pharmacy Enterprise, Beijing, China) using 13 standard positive sera and 306 clinical sera. In both laboratory evaluation and clinical application, UPT-LF assay showed the best sensitivity (99.19%) and detection agreement (97.43% for the adjusted agreement) with true results. The concordance rate between UPT-LF and ELISA, as shown by correlative regression analysis, was the highest (R-2 = 0.6389), whereas that between UPT-LF and AUSAB was the lowest (R-2 = 0.5702). In conclusion, UPT-LF assay for quantitative detection of HBsAb is sensitive and rapid, promising this new assay a bright future. (c) 2009 Published by Elsevier Inc.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 42 条
[1]   Development of a microfluidic device for detection of pathogens in oral samples using upconverting phosphor technology (UPT) [J].
Abrams, William R. ;
Barber, Cheryl A. ;
McCann, Kurt ;
Tong, Gary ;
Chen, Zongyuan ;
Mauk, Michael G. ;
Wang, Jing ;
Volkov, Alex ;
Bourdelle, Pete ;
Corstjensd, Paul L. A. M. ;
Zuiderwijk, Michel ;
Kardos, Keith ;
Li, Shang ;
Tanke, Hans J. ;
Niedbala, R. Sam ;
Malamud, Daniel ;
Bau, Haim .
ORAL-BASED DIAGNOSTICS, 2007, 1098 :375-388
[2]   Immunization with an adjuvant hepatitis B vaccine after liver transplantation for hepatitis B-related disease [J].
Bienzle, U ;
Günther, M ;
Neuhaus, R ;
Vandepapeliere, P ;
Vollmar, J ;
Lun, A ;
Neuhaus, P .
HEPATOLOGY, 2003, 38 (04) :811-819
[3]   Immunogenicity of a recombinant hepatitis a vaccine in adults [J].
Bock, HL ;
Kruppenbacher, J ;
Sanger, R ;
Hobel, W ;
Clemens, R ;
Jilg, W .
ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (19) :2226-2231
[4]   Immunogenicity and safety assessment of the Cuban recombinant hepatitis B vaccine in healthy adults [J].
Cinza Estevez, Zurina ;
Aguilar Betancourt, Aristides ;
Muzio Gonzalez, Verena ;
Figueroa Baile, Nelvis ;
Valenzuela Silva, Carmen ;
Hernandez Bernal, Francisco ;
Penton Arias, Eduardo ;
Delhanty Fernandez, Aurora ;
Martin Olazabal, Nelia ;
del Rio Martin, Amaurys ;
Leal Batista, Lester ;
Veliz Rios, Gloria ;
Hernandez Hernandez, Hctor ;
Blanco Hernandez, Aracelis ;
Perez Lugo, Evelyn ;
de la Torre Cruz, Joel ;
Batista Marchec, Bertha L. ;
Alvarez Falcon, Leovaldo ;
Trujillo Brito, Jannet ;
Ortega Leon, Darien ;
Lopez Saura, Pedro .
BIOLOGICALS, 2007, 35 (02) :115-122
[5]  
Corstjens P, 2001, CLIN CHEM, V47, P1885
[6]   A user-friendly, highly sensitive assay to detect the IFN-γ secretion by T cells [J].
Corstjens, Paul L. A. M. ;
Zuiderwijk, Michel ;
Tanke, Hans J. ;
van der Ploeg-van Schip, Jolien J. ;
Ottenhoff, Tom H. M. ;
Geluk, Annemiek .
CLINICAL BIOCHEMISTRY, 2008, 41 (06) :440-444
[7]   Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum [J].
Corstjens, Paul L. A. M. ;
van Lieshout, Lisette ;
Zuiderwijk, Michel ;
Kornelis, Dieuwke ;
Tanke, Hans J. ;
Deelder, Andre M. ;
van Dam, Govert J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :171-176
[8]   Lateral-flow and up-converting phosphor reporters to detect single-stranded nucleic acids in a sandwich-hybridization assay [J].
Corstjens, PLAM ;
Zuiderwijk, M ;
Nilsson, M ;
Feindt, H ;
Niedbala, RS ;
Tanke, HJ .
ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) :191-200
[9]   Immunogenicity of recombinant hepatitis B virus vaccine in patients with and without chronic hepatitis C virus infection: A case-control study [J].
Daryani, Naser Ebrahimi ;
Nassiri-Toosi, Mohsen ;
Rashidi, Armin ;
Khodarahmi, Iman .
WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (02) :294-298
[10]  
Gorska Paulina, 2007, Przegl Epidemiol, V61, P393