Reliability of ultrasound for measurement of selected foot structures

被引:137
作者
Crofts, G. [1 ]
Angin, S. [2 ]
Mickle, K. J. [1 ,3 ]
Hill, S. [4 ]
Nester, C. J. [1 ]
机构
[1] Univ Salford, Sch Hlth Sci, Manchester M6 6PU, Lancs, England
[2] Dokuz Eylul Univ, Sch Phys Therapy & Rehabil, TR-35340 Izmir, Turkey
[3] Univ Wollongong, Biomech Res Lab, Wollongong, NSW 2522, Australia
[4] Singapore Gen Hosp, Podiatry Dept, Singapore, Singapore
关键词
Ultrasound; Foot structures; Reliability; PLANTAR FASCIA; MUSCLE; THICKNESS; PRESSURES; ATROPHY; PEOPLE;
D O I
10.1016/j.gaitpost.2013.05.022
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Background: Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). Methods: A sample of 6 females and 4 males (mean age 29.1 +/- 7.2 years, mean BMI 25.5 +/- 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm x 47.1 mm footprint by two operators in the same scanning session. Results: Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. Conclusions: The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function. Crown Copyright (C) 2013 Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 33 条
[1]
Ultrasonographic appearance of the plantar fasciitis [J].
Akfirat, M ;
Sen, C ;
Günes, T .
CLINICAL IMAGING, 2003, 27 (05) :353-357
[2]
Muscular atrophy in diabetic neuropathy: a stereological magnetic resonance imaging study [J].
Andersen, H ;
Gadeberg, PC ;
Brock, B ;
Jakobsen, J .
DIABETOLOGIA, 1997, 40 (09) :1062-1069
[3]
Atrophy of foot muscles [J].
Andersen, H ;
Gjerstad, MD ;
Jakobsen, J .
DIABETES CARE, 2004, 27 (10) :2382-2385
[4]
Bruton A., 2000, PHYSIOTHERAPY, V86, P94, DOI [DOI 10.1016/S0031-9406(05)61211-4, 10.1016/S0031-9406(05)61211-4]
[5]
Bus SA, 2009, DIABETES CARE, V25, P1444
[6]
Ultrasound evaluation of the abductor hallucis muscle: Reliability study [J].
Cameron, Alyse F. M. ;
Rome, Keith ;
Hing, Wayne A. .
JOURNAL OF FOOT AND ANKLE RESEARCH, 2008, 1 (1)
[7]
Reproducibility of sonographic measurement of thickness and echogenicity of the plantar fascia [J].
Cheng, Ju-Wen ;
Tsai, Wen-Chung ;
Yu, Tung-Yang ;
Huang, Kuo-Yao .
JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (01) :14-19
[8]
Contribution of plantar fascia to the increased forefoot pressures in diabetic patients [J].
D'Ambrogi, E ;
Giurato, L ;
D'Agostino, MA ;
Giacomozzi, C ;
Macellari, V ;
Caselli, A ;
Uccioli, L .
DIABETES CARE, 2003, 26 (05) :1525-1529
[9]
Ultrasonography of plantar soft tissues thickness in young people with diabetes [J].
Duffin, AC ;
Lam, A ;
Kidd, R ;
Chan, AKF ;
Donaghue, KC .
DIABETIC MEDICINE, 2002, 19 (12) :1009-1013
[10]
INFLUENCE OF EXTRINSIC PLANTAR FLEXORS ON FOREFOOT LOADING DURING HEEL RISE [J].
FERRIS, L ;
SHARKEY, NA ;
SMITH, TS ;
MATTHEWS, DK .
FOOT & ANKLE INTERNATIONAL, 1995, 16 (08) :464-473