High temporal resolution volume heart imaging with multirow computed tomography

被引:19
作者
Bruder, H [1 ]
Schaller, S [1 ]
Ohnesorge, B [1 ]
Mertelmeier, T [1 ]
机构
[1] Siemens AG, D-91050 Erlangen, Germany
来源
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2 | 1999年 / 3661卷
关键词
multirow computed tomography; reconstruction; area detector; volume heart imaging; time resolution; time sensitivity profile; cardiac imaging; retrospective ECG-gating;
D O I
10.1117/12.348597
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Functional cardiac imaging with 3rd generation CT scanners is challenging, because the temporal resolution seems to be limited to approximately 2/3 of the rotation time of the gantry. We propose a new method for high temporal resolution volume heart imaging with multirow detectors based on a retrospective electrocardiogram(ECG)-gated rebinning procedure. The limited time resolution is overcome using time consistent projection data retrieved from more than one cardiac cycle. In principle the method provides volume heart imaging with adjustable time resolution at arbitrary cardiac phases. It can be applied both for spiral and axial scan imaging. The presented study is based on computer simulations incorporating a model of the human heart taking into account anatomy, motion and heart rate variability. For multirow detectors we were able to show that good image quality can be obtained even during systole with temporal resolution which even exceeds that provided by an Electron Beam Scanner (EBT) in standard mode of operation. Using an area detector with detector height > 3cm (center of rotation) the total measurement time is within one breathhold for complete volume imaging of the heart. Furthermore, freezing motion of the coronary arteries during enddiastole allows high quality 3D display of coronary anatomy.
引用
收藏
页码:420 / 432
页数:13
相关论文
共 14 条
[1]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[2]  
FLOHR T, 1997, RADIOLOGY, V205, P214
[3]  
Kachelriess M, 1998, RADIOLOGY, V209P, P323
[4]   Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Kalender, WA .
MEDICAL PHYSICS, 1998, 25 (12) :2417-2431
[5]  
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI
[6]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[7]  
KAMATH MV, 1993, CRIT REV BIOMED ENG, V21, P245
[8]  
MOSHAGE W, 1998, COMMUNICATION
[9]   OPTIMAL SHORT SCAN CONVOLUTION RECONSTRUCTION FOR FANBEAM CT [J].
PARKER, DL .
MEDICAL PHYSICS, 1982, 9 (02) :254-257
[10]   Heart rate change as a function of age, tidal volume and body position when breathing using voluntary cardiorespiratory synchronization [J].
Patterson, R ;
Kaiser, D .
PHYSIOLOGICAL MEASUREMENT, 1997, 18 (03) :183-189