Liquid chromatography-mass spectrometry in metabolomics research: Mass analyzers in ultra high pressure liquid chromatography coupling

被引:119
作者
Forcisi, Sara [1 ]
Moritz, Franco [1 ]
Kanawati, Basem [1 ]
Tziotis, Dimitrios [1 ]
Lehmann, Rainer [3 ,4 ]
Schmitt-Kopplin, Philippe [1 ,2 ]
机构
[1] German Res Ctr Environm Hlth, Helmholtz Zentrum Munchen, Res Unit Analyt BioGeoChem, D-85764 Neuherberg, Germany
[2] Tech Univ Munich, Chair Analyt Food Chem, D-85354 Freising Weihenstephan, Germany
[3] Univ Tubingen Hosp, Cent Lab, Div Clin Chem & Pathobiochem, D-72076 Tubingen, Germany
[4] Univ Tubingen, Paul Langherans Inst Tuebingen, D-72076 Tubingen, Germany
关键词
LC-MS; ICR-FT/MS; TOF-MS; Non-targeted metabolomics; Mass difference networking; TIME-OF-FLIGHT; MAGNETIC-RESONANCE SPECTROSCOPY; HIGH-RESOLUTION H-1-NMR; MS-BASED METABOLOMICS; LC-MS; ELECTROSPRAY-IONIZATION; CAPILLARY-ELECTROPHORESIS; HYDROPHILIC INTERACTION; ION-TRAP; COMPARING CAPILLARY;
D O I
10.1016/j.chroma.2013.04.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present review gives an introduction into the concept of metabolomics and provides an overview of the analytical tools applied in non-targeted metabolomics with a focus on liquid chromatography (LC). LC is a powerful analytical tool in the study of complex sample matrices. A further development and configuration employing Ultra-High Pressure Liquid Chromatography (UHPLC) is optimized to provide the largest known liquid chromatographic resolution and peak capacity. Reasonably UHPLC plays an important role in separation and consequent metabolite identification of complex molecular mixtures such as bio-fluids. The most sensitive detectors for these purposes are mass spectrometers. Almost any mass analyzer can be optimized to identify and quantify small pre-defined sets of targets; however, the number of analytes in metabolomics is far greater. Optimized protocols for quantification of large sets of targets may be rendered inapplicable. Results on small target set analyses on different sample matrices are easily comparable with each other. In non-targeted metabolomics there is almost no analytical method which is applicable to all different matrices due to limitations pertaining to mass analyzers and chromatographic tools. The specifications of the most important interfaces and mass analyzers are discussed. We additionally provide an exemplary application in order to demonstrate the level of complexity which remains intractable up to date. The potential of coupling a high field Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (ICR-FT/MS), the mass analyzer with the largest known mass resolving power, to UHPLC is given with an example of one human pre-treated plasma sample. This experimental example illustrates one way of overcoming the necessity of faster scanning rates in the coupling with UHPLC. The experiment enabled the extraction of thousands of features (analytical signals). A small subset of this compositional space could be mapped into a mass difference network whose topology shows specificity toward putative metabolite classes and retention time. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 65
页数:15
相关论文
共 162 条
[1]   Comparing Capillary Electrophoresis - Mass Spectrometry Fingerprints of Urine Samples Obtained after Intake of Coffee, Tea, or Water [J].
Allard, Erik ;
Backstrom, Daniel ;
Danielsson, Rolf ;
Sjobberg, J. R. ;
Bergquist, Jonas .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :8946-8955
[2]  
BALES JR, 1984, CLIN CHEM, V30, P426
[3]   Capillary electrophoresis as a metabolomics tool for non-targeted fingerprinting of biological samples [J].
Barbas, C. ;
Moraes, Edgar P. ;
Villasenor, A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (04) :823-831
[4]   Evaluation of matrix effects in metabolite profiling based on capillary liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry [J].
Boettcher, Christoph ;
v. Roepenack-Lahaye, Edda ;
Willscher, Edith ;
Scheel, Dierk ;
Clemens, Stephan .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1507-1513
[5]   Attachment of Chloride Anion to Sugars: Mechanistic Investigation and Discovery of a New Dopant for Efficient Sugar Ionization/Detection in Mass Spectrometers [J].
Boutegrabet, Lemia ;
Kanawati, Basem ;
Gebefuegi, Istvan ;
Peyron, Dominique ;
Cayot, Philippe ;
Gougeon, Regis D. ;
Schmitt-Kopplin, Philippe .
CHEMISTRY-A EUROPEAN JOURNAL, 2012, 18 (41) :13059-13067
[6]   Ab initio prediction of metabolic networks using Fourier transform mass spectrometry data [J].
Breitling, Rainer ;
Ritchie, Shawn ;
Goodenowe, Dayan ;
Stewart, Mhairi L. ;
Barrett, Michael P. .
METABOLOMICS, 2006, 2 (03) :155-164
[7]   General unknown screening in hair by liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) [J].
Broecker, Sebastian ;
Herre, Sieglinde ;
Pragst, Fritz .
FORENSIC SCIENCE INTERNATIONAL, 2012, 218 (1-3) :68-81
[8]   Liquid chromatographic-mass spectrometric analysis of phospholipids. Chromatography, ionization and quantification [J].
Brouwers, Jos F. .
BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (11) :763-775
[9]   Evaluation of a protocol for metabolic profiling studies on human blood plasma by combined ultra-performance liquid chromatography/mass spectrometry: From extraction to data analysis [J].
Bruce, Stephen J. ;
Jonsson, Par ;
Antti, Henrik ;
Cloarec, Olivier ;
Trygg, Johan ;
Marklund, Stefan L. ;
Moritz, Thomas .
ANALYTICAL BIOCHEMISTRY, 2008, 372 (02) :237-249
[10]   Antibiotic treatment partially protects against type 1 diabetes in the Bio-Breeding diabetes-prone rat. Is the gut flora involved in the development of type 1 diabetes? [J].
Brugman, S. ;
Klatter, F. A. ;
Visser, J. T. J. ;
Wildeboer-Veloo, A. C. M. ;
Harmsen, H. J. M. ;
Rozing, J. ;
Bos, N. A. .
DIABETOLOGIA, 2006, 49 (09) :2105-2108