摘要
The authors evaluated a new Cassette Serum Barbiturates fluorescence polarization immunoassay (FPIA) on the COBAS INTEGRA. The assay was calibrated with secobarbital standards at 0, 0.5, and 4.0 mu g/mL. The assay range was 0.030 to 80 mu g/mL using an automatic 1/20 postdilution feature. Precision was established for two COBAS INTEGRA instruments for ten days by assaying secobarbital target concentrations ranging from 0.125 to 2.2 mu g/mL. The coefficients of variation (CV) for the above target concentrations for the first instrument ranged from 2.7% to 8.3%, and for a second instrument, 3.8 to 8.3%. Seven clinically elevated bilirubin samples were spiked with 0.46 and 1.77 mu g/mL secobarbital. Bilirubin interference was less than 10.9 and less than 7.9%, respectively. The average recovery ranged from 85% to 94%, The mean difference in recovery in serum versus plasma was less than or equal to 3%. Fifty-two clinical samples were analyzed for butalbital, pentobarbital, secobarbital, and phenobarbital by GC/MS, and the results were compared to the new Cassette Serum Barbiturates FPIA. The diagnostic sensitivity and specificity were 95% and 100%, respectively. Both FPIA and GC/MS assays are clinically efficacious for monitoring serum barbiturates.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 9 条
[1]   A SCREENING METHOD FOR THE RAPID DETECTION OF BARBITURATES IN SERUM BY MEANS OF TANDEM MASS-SPECTROMETRY [J].
BRZEZINKA, H ;
BOLD, P ;
BUDZIKIEWICZ, H .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (06) :346-350
[2]  
CLARKE EGC, 1969, ISOLATION IDENTIFICA, P195
[3]   RAPID TOXICOLOGICAL SCREENING OF BARBITURATES IN PLASMA BY WIDE-BORE CAPILLARY GAS-CHROMATOGRAPHY AND NITROGEN PHOSPHORUS DETECTION [J].
COUDORE, F ;
ALAZARD, JM ;
PAIRE, M ;
ANDRAUD, G ;
LAVARENNE, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (02) :109-113
[4]   EMIT-ST DRUG DETECTION SYSTEM FOR SCREENING OF BARBITURATES AND BENZODIAZEPINES IN SERUM [J].
DROST, RH ;
PLOMP, TA ;
MAES, RAA .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1982, 19 (03) :303-312
[5]   SYSTEMATIC TOXICOLOGICAL ANALYSIS OF DRUGS AND THEIR METABOLITES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MAURER, HH .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 580 (1-2) :3-41
[6]  
*ROCH DIAGN, 1998, METH MAN SER BARB CO
[7]  
SASSE EA, 1997, HDB ANAL THERAPEUTIC, P223
[8]  
SPIEHLER V, 1990, THER DRUG MONIT CLIN, V11, P7
[9]  
WILSON J, 1994, ABUSED DRUGS, V2