Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung

被引:22
作者
Chetty, IJ [1 ]
Rosu, M [1 ]
McShan, DL [1 ]
Fraass, BA [1 ]
Balter, JM [1 ]
Ten Haken, RK [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
Monte Carlo; lung GTV; center-of-mass breathing motion; fluence convolution; dose convolution;
D O I
10.1118/1.1669083
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have applied convolution methods to account for some of the effects of respiratory induced motion in clinical treatment planning of the lung. The 3-D displacement of the GTV center-of-mass (COM) as determined from breath-hold exhale and inhale CT scans was used to approximate the breathing induced motion. The time-course of the GTV-COM was estimated using a probability distribution function (PDF) previously derived from diaphragmatic motion [Med. Phys. 26, 715720 (1990)] but also used by others for treatment planning in the lung [Int. J. Radiat. Oncol., Biol., Phys. 53, 822-834 (2002); Med. Phys. 30, 1086-1095 (2003)]. We have implemented fluence and dose convolution methods within a Monte Carlo based dose calculation system with the intent of comparing these approaches for planning in the lung. All treatment plans in this study have been calculated with Monte Carlo using the breath-hold exhale CT data sets. An analysis of treatment plans for 3 patients showed substantial differences (hot and cold spots consistently greater than +/-15%) between the motion convolved and static treatment plans. As fluence convolution accounts for the spatial variance of the dose distribution in the presence of tissue inhomogeneities, the doses were approximately 5% greater than those calculated with dose convolution in the vicinity of the lung. DVH differences between the static, fluence and dose convolved distributions for the CTV were relatively small, however, larger differences were observed for the PTV. An investigation of the effect of the breathing PDF asymmetry on the motion convolved dose distributions showed that reducing the asymmetry resulted in increased hot and cold spots in the motion convolved distributions relative to the static cases. In particular, changing from an asymmetric breathing function to one that is symmetric results in an increase in the hot/cold spots of +/-15% relative to the static plan. This increase is not unexpected considering that the target spends relatively more time at inhale as the asymmetry decreases (note that the treatment plans were generated using the exhale CT scans). (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:925 / 932
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]   Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging [J].
Balter, JM ;
Lam, KL ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :939-943
[3]  
BECKHAM WA, 1999, PHYS MED BIOL, V47, P715
[4]   A virtual source model for Monte Carlo modeling of arbitrary intensity distributions [J].
Chetty, I ;
DeMarco, JJ ;
Solberg, TD .
MEDICAL PHYSICS, 2000, 27 (01) :166-172
[5]   A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study [J].
Chetty, IJ ;
Rosu, M ;
Tyagi, N ;
Marsh, LH ;
McShan, DL ;
Balter, JM ;
Fraass, BA ;
Ten Haken, RK .
MEDICAL PHYSICS, 2003, 30 (07) :1776-1780
[6]   Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media [J].
Chetty, IJ ;
Charland, PM ;
Tyagi, N ;
McShan, DL ;
Fraass, BA ;
Bielajew, AF .
MEDICAL PHYSICS, 2003, 30 (04) :563-573
[7]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2001-2011
[8]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2012-2020
[9]   Dose correlation for thoracic motion in radiation therapy of breast cancer [J].
Ding, MS ;
Li, JS ;
Deng, J ;
Fourkal, E ;
Ma, CM .
MEDICAL PHYSICS, 2003, 30 (09) :2520-2529
[10]   The theoretical benefit of beam fringe compensation and field size reduction for iso-normal tissue complication probability dose escalation in radiotherapy of lung cancer [J].
Engelsman, M ;
Remeijer, P ;
van Herk, M ;
Mijnheer, B ;
Damen, E .
MEDICAL PHYSICS, 2003, 30 (06) :1086-1095