Fast wave forms for pulsed electrochemical detection of glucose by incorporation of reductive desorption of oxidation products

被引:56
作者
Jensen, MB [1 ]
Johnson, DC [1 ]
机构
[1] IOWA STATE UNIV SCI & TECHNOL,DEPT CHEM,AMES,IA 50011
关键词
D O I
10.1021/ac960828x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical activity of Au electrodes held at constant potential for anodic detection of carbohydrates In alkaline media eventually decays Co zero, This loss of response is a consequence of the accumulation of adsorbed oxidation products on the electrode surface. Although it is well-known that these ''poisons''' can be removed by oxidative desorption simultaneously with formation of surface oxide, pvc have discovered that electrodes fouled during the detection of glucose yield a cathodic peak at -0.77 V vs SCE resulting from reductive desorption of these species. incorporation of the reductive desorption process into wave forms for pulsed electrochemical detection (PED) permits a significant decrease in the time periods traditionally allowed for the oxidative and reductive reactivation of the electrode with a resulting increase in wave form frequency. A 6,7-Hz wave form using E-red = -1.00 V (t(red) = 10 ms), E-oxd = +0.60 V (t(oxd) = 10 ms), and E-det = +0.10 V (t(del) = 50 ms, t(int) = 10 ms) is applied for detection of glucose in a LC-PED system and is demonstrated to yield a subpicomole detection limit with a linear dynamic range extending over three decades.
引用
收藏
页码:1776 / 1781
页数:6
相关论文
共 17 条
[1]   ELECTROSYNTHESIS IN AQUEOUS-MEDIUM - A KINETIC-STUDY OF THE ELECTROCATALYTIC OXIDATION OF OXYGENATED ORGANIC-MOLECULES [J].
BELGSIR, EM ;
BOUHIER, E ;
YEI, HE ;
KOKOH, KB ;
BEDEN, B ;
HUSER, H ;
LEGER, JM ;
LAMY, C .
ELECTROCHIMICA ACTA, 1991, 36 (07) :1157-1164
[2]  
GILMAN S, 1967, ELECTROANALYTICAL CH, V2, P111
[3]   LIQUID-CHROMATOGRAPHY WITH PULSED ELECTROCHEMICAL DETECTION AT GOLD AND PLATINUM-ELECTRODES [J].
JOHNSON, DC ;
LACOURSE, WR .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :A589-A597
[4]  
JOHNSON DC, 1995, CARBOHYDRATE ANAL HI, P391
[5]  
JOHNSON DC, 1988, ANAL CHIM ACTA, V204, P1
[6]   OPTIMIZATION OF WAVE-FORMS FOR PULSED AMPEROMETRIC DETECTION (PAD) OF CARBOHYDRATES FOLLOWING SEPARATION BY LIQUID-CHROMATOGRAPHY [J].
LACOURSE, WR ;
JOHNSON, DC .
CARBOHYDRATE RESEARCH, 1991, 215 (01) :159-178
[7]  
LACOURSE WR, 1993, ANALUSIS, V21, P181
[8]   OPTIMIZATION OF WAVE-FORMS FOR PULSED AMPEROMETRIC DETECTION OF CARBOHYDRATES BASED ON PULSED VOLTAMMETRY [J].
LACOURSE, WR ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1993, 65 (01) :50-55
[9]  
LAREW LA, 1989, J ELECTROANAL CHEM, V262, P167
[10]   PULSED AMPEROMETRIC DETECTION OF CARBOHYDRATES SEPARATED BY CAPILLARY ELECTROPHORESIS [J].
LU, WZ ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2878-2881