Use of activated graphitized carbon chips for liquid chromatography/mass spectrometric and tandem mass spectrometric analysis of tryptic glycopeptides

被引:50
作者
Alley, William R., Jr. [1 ]
Mechref, Yehia [1 ,2 ]
Novotny, Milos V. [1 ,2 ]
机构
[1] Indiana Univ, Natl Ctr Glycom & Glycoprote, Dept Chem, Bloomington, IN 47405 USA
[2] Indiana Univ, METACyt Biochem Anal Ctr, Dept Chem, Bloomington, IN 47405 USA
关键词
ELECTRON-TRANSFER DISSOCIATION; CARBOHYDRATE HETEROGENEITY; OLIGOSACCHARIDES; SERUM; GLYCANS; POWDER;
D O I
10.1002/rcm.3899
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Protein glycosylation has a significant medical importance as changes in glycosylation patterns have been associated with a number of diseases. Therefore, monitoring potential changes in glycan profiles, and the microheterogeneities associated with glycosylation sites, are becoming increasingly important in the search for disease biomarkers. Highly efficient separations and sensitive methods must be developed to effectively monitor changes in the glycoproteome. These methods must not discriminate against hydrophobic or hydrophilic analytes. The use of activated graphitized carbon as a desalting media and a stationary phase for the purification and the separation of glycans, and as a stationary phase for the separation of small glycopeptides, has previously been reported. Here, we describe the use of activated graphitized carbon as a stationary phase for the separation of hydrophilic tryptic glycopeptides, employing a chip-based liquid chromatographic (LC) system. The capabilities of both activated graphitized carbon and C-18 LC chips for the characterization of the glycopeptides appeared to be comparable. Adequate retention time reproducibility was achieved for both packing types in the chip format. However, hydrophilic glycopeptides were preferentially retained on the activated graphitized carbon chip, thus allowing the identification of hydrophilic glycopeptides which were not effectively retained on C-18 chips. On the other hand, hydrophobic glycopeptides were better retained on C-18 chips. Characterization of the glycosylation sites of glycoproteins possessing both hydrophilic and hydrophobic glycopeptides is comprehensively achieved using both media. This is feasible considering the limited amount of sample required per analysis (<1 pmol). The performance of both media also appeared comparable when analyzing a four-protein mixture. Similar sequence coverage and MASCOT ion scores were observed for all proteins when using either stationary phase. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:495 / 505
页数:11
相关论文
共 25 条
[1]   Characterization of glycopeptides by combining collision-induced dissociation and electron-transfer dissociation mass spectrometry data [J].
Alley, William R., Jr. ;
Mechref, Yehia ;
Novotny, Milos V. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (01) :161-170
[2]   Determination of N-glycosylation sites and site heterogeneity in glycoproteins [J].
An, HJ ;
Peavy, TR ;
Hedrick, JL ;
Lebrilla, CB .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5628-5637
[3]   Profiling of glycans in serum for the discovery of potential biomarkers for ovarian cancer [J].
An, Hyun Joo ;
Miyamoto, Suzanne ;
Lancaster, Katherine S. ;
Kirmiz, Crystal ;
Li, Bensheng ;
Lam, Kit S. ;
Leiserowitz, Gary S. ;
Lebrilla, Carlito B. .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (07) :1626-1635
[4]   Electron transfer dissociation of N-glycopeptides:: loss of the entire N-glycosylated asparagine side chain [J].
Catalina, M. Isabel ;
Koeleman, Carolien A. M. ;
Deelder, Andre M. ;
Wuhrer, Manfred .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (06) :1053-1061
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF OLIGOSACCHARIDE ALDITOLS AND GLYCOPEPTIDES ON A GRAPHITIZED CARBON COLUMN [J].
DAVIES, M ;
SMITH, KD ;
HARBIN, AM ;
HOUNSELL, EF .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :125-131
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF GLYCOPEPTIDES AND OLIGOSACCHARIDES ON GRAPHITIZED CARBON COLUMNS [J].
FAN, JQ ;
KONDO, A ;
KATO, I ;
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1994, 219 (02) :224-229
[7]   Retention characteristics and practical applications of carbon sorbents [J].
Forgács, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) :229-243
[8]  
GOETZ JA, 2009, GLYCOCONJUG IN PRESS
[9]   Analysis of carbohydrate heterogeneity in a glycoprotein using liquid chromatography mass spectrometry and liquid chromatography with tandem mass spectrometry [J].
Kawasaki, N ;
Ohta, M ;
Hyuga, S ;
Hashimoto, O ;
Hayakawa, T .
ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) :297-303
[10]   Application of liquid chromatography/mass spectrometry and liquid chromatography with tandem mass spectrometry to the analysis of the site-specific carbohydrate heterogeneity in erythropoietin [J].
Kawasaki, N ;
Ohta, M ;
Hyuga, S ;
Hyuga, M ;
Hayakawa, T .
ANALYTICAL BIOCHEMISTRY, 2000, 285 (01) :82-91