Nonlinearity parameter for tissue-mimicking materials

被引:77
作者
Dong, F
Madsen, EL
MacDonald, MC
Zagzebski, JA
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Acuson Inc, Mt View, CA 94043 USA
关键词
tissue-mimicking materials; nonlinearity parameter; B A; second harmonic;
D O I
10.1016/S0301-5629(99)00016-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A finite amplitude insert-substitution method has been used to determine the ultrasonic nonlinearity parameter BIA of nine versions of water-based, macroscopically uniform ultrasonically tissue-mimicking (TM) nonfat and fat materials. In this method, the amplitude of the second harmonic following transmission through degassed distilled water with known B/A (B/A = 5.2) and the amplitude of the second harmonic following transmission through the unknown sample are measured. The ratio of these amplitudes allows calculation of the B/A of the sample. Measured B/A values of the nonfat materials range from 5.6 to 6.6, These values compare favorably with published values for nonfat soft tissues. In contrast, the measured B/A values for two tissue-mimicking fat materials are 9.8 and 11.1; these two values represent the low and high end of B/A for most fresh fatty tissues. For comparison, B/A was measured for two commonly available uniform materials, corn oil and ethylene glycol, and the results are in good agreement with published values. (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:831 / 838
页数:8
相关论文
共 29 条
[1]  
*AIUM TECHN STAND, 1990, STAND METH MEAS PERF
[2]  
Bevington P.R., 1969, DATA REDUCTION ERROR, P56
[3]   NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL [J].
BURLEW, MM ;
MADSEN, EL ;
ZAGZEBSKI, JA ;
BANJAVIC, RA ;
SUM, SW .
RADIOLOGY, 1980, 134 (02) :517-520
[4]  
Burns PN, 1994, P IEEE ULTRASON S, V3, P1547
[6]  
Duck F., 1990, PHYS PROPERTIES TISS, P98
[7]   DEPENDENCE OF ULTRASONIC NONLINEAR PARAMETER B/A ON FAT [J].
ERRABOLU, RL ;
SEHGAL, CM ;
GREENLEAF, JF .
ULTRASONIC IMAGING, 1987, 9 (03) :180-194
[8]   MEASUREMENT OF ULTRASONIC NONLINEAR PARAMETER IN EXCISED FAT TISSUES [J].
ERRABOLU, RL ;
SEHGAL, CM ;
BAHN, RC ;
GREENLEAF, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (02) :137-146
[9]   Real-time assessment of the parameter of nonlinearity in tissue using ''nonlinear shadowing'' [J].
Fatemi, M ;
Greenleaf, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1215-1228
[10]  
Forsberg F, 1997, INT J IMAG SYST TECH, V8, P69, DOI 10.1002/(SICI)1098-1098(1997)8:1<69::AID-IMA9>3.0.CO