Noninvasive evaluation of electrical stimulation impacts on muscle hemodynamics via integrating diffuse optical spectroscopies with muscle stimulator

被引:15
作者
Shang, Yu [1 ]
Lin, Yu [1 ]
Henry, Brad A. [1 ]
Cheng, Ran [1 ]
Huang, Chong [1 ]
Chen, Li [2 ]
Shelton, Brent J. [2 ]
Swartz, Karin R. [3 ]
Salles, Sara S. [4 ]
Yu, Guoqiang [1 ]
机构
[1] Univ Kentucky, Dept Biomed Engn, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Biostat, Lexington, KY 40536 USA
[3] Univ Kentucky, Dept Neurosurg, Lexington, KY 40536 USA
[4] Univ Kentucky, Dept Phys Med & Rehabil, Lexington, KY 40536 USA
基金
美国国家卫生研究院;
关键词
electrical stimulation; diffuse correlation spectroscopy; muscle; blood flow; oxygenation; motion artifact; gating algorithm; NEAR-INFRARED SPECTROSCOPY; SPINAL-CORD-INJURY; TUMOR BLOOD-FLOW; SKELETAL-MUSCLE; LEG ULCERS; CEREBRAL HEMODYNAMICS; FORCE GENERATION; PRESSURE ULCERS; PULSED CURRENT; OXYGENATION;
D O I
10.1117/1.JBO.18.10.105002
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Technologies currently available for the monitoring of electrical stimulation (ES) in promoting blood circulation and tissue oxygenation are limited. This study integrated a muscle stimulator with a diffuse correlation spectroscopy (DCS) flow-oximeter to noninvasively quantify muscle blood flow and oxygenation responses during ES. Ten healthy subjects were tested using the integrated system. The muscle stimulator delivered biphasic electrical current to right leg quadriceps muscle, and a custom-made DCS flow-oximeter was used for simultaneous measurements of muscle blood flow and oxygenation in both legs. To minimize motion artifact of muscle fibers during ES, a novel gating algorithm was developed for data acquisition at the time when the muscle was relaxed. ES at 2, 10, and 50 Hz were applied for 20 min on each subject in three days sequentially. Results demonstrate that the 20-min ES at all frequencies promoted muscle blood flow significantly. However, only the ES at 10 Hz resulted in significant and persistent increases in oxy-hemoglobin concentration during and post ES. This pilot study supports the application of the integrated system to quantify tissue hemodynamic improvements for the optimization of ES treatment in patients suffering from diseases caused by poor blood circulation and low tissue oxygenation (e.g., pressure ulcer). (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:11
相关论文
共 71 条
[1]
Al Malty AM, 2007, MED SCI MONITOR, V13, pCR147
[2]
Bagshaw CR., 1982, Muscle Contraction
[3]
Noninvasive observation of skeletal muscle contraction using near-infrared time-resolved reflectance and diffusing-wave spectroscopy [J].
Belau, Markus ;
Ninck, Markus ;
Hering, Gernot ;
Spinelli, Lorenzo ;
Contini, Davide ;
Torricelli, Alessandro ;
Gisler, Thomas .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (05)
[4]
SCATTERING AND IMAGING WITH DIFFUSING TEMPORAL FIELD CORRELATIONS [J].
BOAS, DA ;
CAMPBELL, LE ;
YODH, AG .
PHYSICAL REVIEW LETTERS, 1995, 75 (09) :1855-1858
[5]
Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation [J].
Boas, DA ;
Yodh, AG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (01) :192-215
[6]
A simple model of force generation by skeletal muscle during dynamic isometric contractions [J].
Bobet, J ;
Stein, RB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) :1010-1016
[7]
Protocol for the successful treatment of pressure ulcers [J].
Brem, H ;
Lyder, C .
AMERICAN JOURNAL OF SURGERY, 2004, 188 (1A) :9S-17S
[8]
Cerebral hemodynamics in preterm infants during positional intervention measured with diffuse correlation spectroscopy and transcranial Doppler ultrasound [J].
Buckley, Erin M. ;
Cook, Noah M. ;
Durduran, Turgut ;
Kim, Meeri N. ;
Zhou, Chao ;
Choe, Regine ;
Yu, Guoqiang ;
Shultz, Susan ;
Sehgal, Chandra M. ;
Licht, Daniel J. ;
Arger, Peter H. ;
Putt, Mary E. ;
Hurt, Hallam ;
Yodh, Arjun G. .
OPTICS EXPRESS, 2009, 17 (15) :12571-12581
[9]
Noninvasive optical evaluation of spontaneous low frequency oscillations in cerebral hemodynamics [J].
Cheng, Ran ;
Shang, Yu ;
Hayes, Don, Jr. ;
Saha, Sibu P. ;
Yu, Guoqiang .
NEUROIMAGE, 2012, 62 (03) :1445-1454
[10]
Cosmo P, 2000, SCAND J PLAST RECONS, V34, P61