High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable I.: Experiments with 25 cm x 4.6 mm ID, 5 μm ODS columns

被引:64
作者
Lestremau, F
Cooper, A
Szucs, R
David, F
Sandra, P
机构
[1] Univ Ghent, Pfizer Analyt Res Ctr, B-9000 Ghent, Belgium
[2] Pfizer Global R&D, Analyt R&D, Sittingbourne Res Ctr, Sittingbourne ME9 8AG, Kent, England
[3] Pfizer Ltd, Analyt R&D, Sandwich CT13 9NJ, Kent, England
关键词
liquid chromatography; high-efficiency; temperature; coupled columns;
D O I
10.1016/j.chroma.2005.12.112
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 mu m ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350 bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 37 条
  • [1] ANTIA FD, 1988, J CHROMATOGR, V435, P1
  • [2] Rapid and high-resolution analysis of geometric polyprenol homologues by connected octadecylsilylated monolithic silica columns in high-performance liquid chromatography
    Bamba, T
    Fukusaki, EI
    Nakazawa, Y
    Kobayashi, A
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (04) : 293 - 296
  • [3] PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH 220000 PLATES
    BERGER, TA
    WILSON, WH
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1451 - 1455
  • [4] HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS
    CHEN, H
    HORVATH, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) : 3 - 20
  • [5] ROLE OF THE TEMPERATURE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PYROCARBON-CONTAINING ADSORBENTS
    COLIN, H
    DIEZMASA, JC
    GUIOCHON, G
    CZAJKOWSKA, T
    MIEDZIAK, I
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 167 (DEC): : 41 - 65
  • [6] Capillary electrochromatography - A high-efficiency micro-separation technique
    Dittmann, MM
    Rozing, GP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) : 63 - 74
  • [7] Superheated water as eluent in high-temperature high-performance liquid chromatographic separations of steroids on a polymer-coated zirconia column
    Fields, SM
    Ye, CQ
    Zhang, DD
    Branch, BR
    Zhang, XJ
    Okafo, N
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) : 197 - 204
  • [8] Greibrokk T, 2001, J SEP SCI, V24, P899, DOI 10.1002/1615-9314(20011201)24:12<899::AID-JSSC899>3.3.CO
  • [9] 2-B
  • [10] High-temperature liquid chromatography
    Greibrokk, T
    Andersen, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 743 - 755