Improved intra-operative reduction control using a three-dimensional mobile image intensifier - A proximal tibia cadaver study

被引:21
作者
Goesling, T. [1 ]
Klingler, K. [2 ]
Geerling, J.
Shin, H. [3 ]
Fehr, M. [2 ]
Krettek, C.
Huefner, T.
机构
[1] Hannover Med Sch, Unfallchirurg Klin, Trauma Dept, FRACS, D-30625 Hannover, Germany
[2] Univ Vet Med Hannover, Dept Domest Anim, D-30559 Hannover, Germany
[3] Hannover Med Sch, D-30625 Hannover, Germany
关键词
Tibia plateau; Computer tomography; Three-dimensional fluoroscopy; Reduction; Intra-articular; Fracture; Intra-operative imaging; 3D imaging; Reduction control; PLATEAU FRACTURES; SPIRAL CT; COMPUTED-TOMOGRAPHY; MANAGEMENT; OSTEOSYNTHESIS; DISPLACEMENT; FIXATION; QUALITY; CLASSIFICATION; RECONSTRUCTION;
D O I
10.1016/j.knee.2008.07.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
This study aimed to analyse whether the precision of a three-dimensional mobile image intensifier (ISO-C 3D) differs from conventional two-dimensional fluoroscopy and high resolution CT scan in a fracture model of the proximal tibia. A depression fracture of the medial plateau (AO/OTA 41-B2.3) was created in 12 formalin-fixed, human cadaver knees. The cartilage of the depression could be positioned above (+1mm, +2mm), below (-1mm, -2mm), or in line with the joint surface. Fluoroscopy, computed tomography (CT) scans, and ISO-C 3D scans (four different protocols: 100 images, 66 images, 50 images, and 33 images) were done for each fracture level. Three independent observers assessed each imaging set. The difference between the estimated reduction and the real reduction was used for statistical analysis. Our hypothesis was that no differences in the precision exist between the imaging techniques (p<0.05). The conventional image intensifier group (0.7 mm +/- 0.67) showed significantly higher deviations than the CT group (0.3 mm +/- 0.43; p<0.001) and significantly higher deviations than all ISO-C 3D groups (0.4-0.5 mm; p<0.001). Of the ISO-C 3D groups, only the scan protocol with the lowest number of images (0.5 mm +/- 0.51) showed significantly lower precision than the CT group (p<0.001). It was concluded that the three-dimensional mobile image intensifier showed higher precision in reduction assessment in a fracture model of the tibial plateau compared to fluoroscopy. High resolution CT scans should remain the standard for post-operative assessment of reduction outside the operating theatre. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 26 条
[1]
Effect of articular step-off and meniscectomy on joint alignment and contact pressures for fractures of the lateral tibial plateau [J].
Bai, B ;
Kummer, FJ ;
Sala, DA ;
Koval, KJ ;
Wolinsky, PR .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (02) :101-106
[2]
Borrelli J, 2002, J ORTHOP TRAUMA, V16, P449, DOI 10.1097/00005131-200208000-00001
[3]
Bicondylar fracture of the posterior aspect of the tibial plateau - A case report and a modified operative approach [J].
Carlson, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :1049-1052
[4]
Cole RJ, 1997, J HAND SURG-AM, V22A, P792
[5]
Eberl R, 2003, UNFALLCHIRURG, V106, P741, DOI 10.1007/s00113-003-0624-7
[6]
Euler E, 2001, UNFALLCHIRURG, V104, P839, DOI 10.1007/s001130170055
[7]
Osteosynthesis of tibial plateau fractures in the elderly - A matched-pair-analysis [J].
Gerich, T ;
Blauth, M ;
Witte, F ;
Krettek, C .
UNFALLCHIRURG, 2001, 104 (01) :50-56
[8]
Hackl W, 2001, UNFALLCHIRURG, V104, P519, DOI 10.1007/s001130170115
[9]
Cost-benefit analysis of intraoperative 3D imaging [J].
Hüfner T. ;
Stübig T. ;
Gösling T. ;
Kendoff D. ;
Geerling J. ;
Krettek C. .
Der Unfallchirurg, 2007, 110 (1) :14-21
[10]
Arthroscopically assisted osteosynthesis for tibial plateau fractures [J].
Hung, SS ;
Chao, EK ;
Chan, YS ;
Yuan, LJ ;
Chung, PCH ;
Chen, CY ;
Lee, MS ;
Wang, CJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (02) :356-363