Potentiometric detection of inorganic anions and cations in capillary electrophoresis with coated-wire ion-selective electrodes

被引:45
作者
Kappes, T [1 ]
Schnierle, P [1 ]
Hauser, PC [1 ]
机构
[1] UNIV BASEL,DEPT CHEM,CH-4056 BASEL,SWITZERLAND
关键词
D O I
10.1016/S0003-2670(97)00309-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of coated-wire ion-selective electrodes of small size with two different PVC-based membranes is described. The electrodes are used as potentiometric end-column detectors for monovalent anions and alkali and alkaline earth metal cations separated by capillary electrophoresis. In comparison to conventional micropipette electrodes these all solid state electrodes showed a similar performance but much higher mechanical robustness and a longer lifetime which was found to be 9 and 8 days, respectively. Calibration curves for Cl- and Ca2+ demonstrate the wide dynamic range of these detectors and detection limits of lower than 10(-7) and 10(-8) M could be achieved using the electrostacking technique.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 16 条
[1]   COATED WIRE ION SELECTIVE ELECTRODES [J].
CATTRALL, RW ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1905-&
[2]   Potentiometric detection for capillary electrophoresis: Determination of organic acids [J].
DeBacker, BL ;
Nagels, LJ .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4441-4445
[3]  
HABER C, 1991, CHIMIA, V45, P117
[4]  
Hauser PC, 1995, J CAPILLARY ELECTROP, V2, P209
[5]   ANION DETECTION IN CAPILLARY ELECTROPHORESIS WITH ION-SELECTIVE MICROELECTRODES [J].
HAUSER, PC ;
RENNER, ND ;
HONG, APC .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :181-186
[6]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[7]   TRANSPORT-PROPERTIES OF ANION-SELECTIVE MEMBRANES BASED ON COBYRINATES AND METALLOPORPHYRIN COMPLEXES AS IONOPHORES [J].
HUSER, M ;
MORF, WE ;
FLURI, K ;
SEILER, K ;
SCHULTHESS, P ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1990, 73 (05) :1481-1496
[8]   NEW NEUTRAL IONOPHORES WITH HIGH BA-2+ SELECTIVITY [J].
KLEINER, T ;
BONGARDT, F ;
VOGTLE, F ;
LAUBLI, MW ;
DINTEN, O ;
SIMON, W .
CHEMISCHE BERICHTE-RECUEIL, 1985, 118 (03) :1071-1077
[9]   A NEW DOUBLE-BARRELED, IONOPHORE-BASED MICROELECTRODE FOR CHLORIDE-IONS [J].
KONDO, Y ;
BUHRER, T ;
SEILER, K ;
FROMTER, E ;
SIMON, W .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1989, 414 (06) :663-668
[10]   BACKGROUND-NOISE IN CAPILLARY ELECTROPHORETIC AMPEROMETRIC DETECTION [J].
LU, WZ ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :200-204