The automatic visualisation of carry-over in high-throughput flow injection analysis mass spectrometry

被引:9
作者
Richmond, R [1 ]
Görlach, E [1 ]
机构
[1] Novartis Pharma AG, Core Technol Area Analyt Unit, CH-4002 Basel, Switzerland
关键词
combinatorial chemistry; flow injection; mass spectrometry; carry-over;
D O I
10.1016/S0003-2670(99)00197-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-throughput flow injection analysis mass spectrometry system (FIA-MS) was developed for the purity estimation of multiple parallel combinatorial chemistry synthetic samples, and has measured over 70 000 samples in two years. An in-house Visual Basic application called RackViewer allows a fast, direct, easy and economic inspection of the estimates at geographically dispersed laboratory workbenches via the corporate network. Due to the large numbers of samples involved, surreptitious inter-sample carry-over represents one threat to the accuracy of these purity estimates. It can become serious when reducing the measurement duty cycle in order to develop faster throughput rates. Over 400 samples drawn equally from five different combinatorial synthetic families were measured to explore this threat. By analogy with the colour rendering of the purity estimates, inter-sample carry-over was automatically calculated for each measurement, colour rendered and then depicted within RackViewer. Our FIA-MS in daily use has a median basal carry-over of 0.88%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 28 条
[1]  
AlvarezPineiro MHE, 1997, HRC-J HIGH RES CHROM, V20, P321
[2]   AN AUTOMATED, OPEN-ACCESS SERVICE TO SYNTHETIC CHEMISTS - THERMOSPRAY MASS-SPECTROMETRY [J].
BROWN, DV ;
DALTON, M ;
PULLEN, FS ;
PERKINS, GL ;
RICHARDS, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) :632-636
[3]   ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF SPHINGANINE ANALOG MYCOTOXINS [J].
CALDAS, ED ;
JONES, AD ;
WINTER, CK ;
WARD, B ;
GILCHRIST, DG .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :196-207
[4]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[5]  
Coran SA, 1998, RAPID COMMUN MASS SP, V12, P281, DOI 10.1002/(SICI)1097-0231(19980331)12:6<281::AID-RCM156>3.0.CO
[6]  
2-M
[7]   AUTOMATED COLD VAPOR FLOW-INJECTION ANALYSIS OF MERCURY AT HIGH-CONCENTRATIONS [J].
CORNS, WT ;
EBDON, LC ;
HILL, SJ ;
STOCKWELL, PB .
JOURNAL OF AUTOMATIC CHEMISTRY, 1991, 13 (06) :267-271
[8]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[9]   SOME IMPLEMENTATIONS OF THE BOXPLOT [J].
FRIGGE, M ;
HOAGLIN, DC ;
IGLEWICZ, B .
AMERICAN STATISTICIAN, 1989, 43 (01) :50-54
[10]   OPTIMIZATION OF INSTRUMENTAL PARAMETERS FOR FLOW-INJECTION ANALYSIS-THERMOSPRAY TANDEM MASS-SPECTROMETRY [J].
GEERDINK, RB ;
KIENHUIS, PGM ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1994, 39 (5-6) :311-319