Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data

被引:56
作者
Sijbers, J [1 ]
Michiels, I [1 ]
Verhoye, M [1 ]
Van Audekerke, J [1 ]
Van der Linden, A [1 ]
Van Dyck, D [1 ]
机构
[1] Univ Antwerp, Vis Lab, Antwerp, Belgium
关键词
restoration; simultaneous EEG/MRI; signal-to-artifact ratio;
D O I
10.1016/S0730-725X(99)00096-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
During a Magnetic Resonance sequence, simultaneously acquired ElectroEncephaloGraphy (EEG) data are compromised by severe pollution due to artifacts originating from the switching of the magnetic field gradients. In this work, it is shown how these artifacts can be strongly reduced or even removed through application of an adaptive artifact restoration scheme. The method has proved to be fully automatic and to retain high frequency EEG information, which is indispensable for many EEG applications. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1383 / 1391
页数:9
相关论文
共 11 条
[1]   Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction [J].
Allen, PJ ;
Polizzi, G ;
Krakow, K ;
Fish, DR ;
Lemieux, L .
NEUROIMAGE, 1998, 8 (03) :229-239
[2]   SIMULTANEOUS RECORDING OF EEG, DC-POTENTIAL AND DIFFUSION-WEIGHTED NMR IMAGING DURING POTASSIUM-INDUCED CORTICAL SPREADING DEPRESSION IN RATS [J].
BUSCH, E ;
HOEHNBERLAGE, M ;
EIS, M ;
GYNGELL, ML ;
HOSSMANN, KA .
NMR IN BIOMEDICINE, 1995, 8 (02) :59-64
[3]  
Felblinger J, 1999, MAGN RESON MED, V41, P715, DOI 10.1002/(SICI)1522-2594(199904)41:4<715::AID-MRM9>3.0.CO
[4]  
2-7
[5]  
FELBLINGER J, 1997, EMRMB 14 ANN M BRUSS, P108
[6]   EEG DURING MR-IMAGING - DIFFERENTIATION OF MOVEMENT ARTIFACT FROM PAROXYSMAL CORTICAL ACTIVITY [J].
HILL, RA ;
CHIAPPA, KH ;
HUANGHELLINGER, F ;
JENKINS, BG .
NEUROLOGY, 1995, 45 (10) :1942-1943
[7]   Simultaneous functional magnetic resonance imaging and electrophysiological recording [J].
HuangHellinger, FR ;
Breiter, HC ;
McCormack, G ;
Cohen, MS ;
Kwong, KK ;
Sutton, JP ;
Savoy, RL ;
Weisskoff, RM ;
Davis, TL ;
Baker, JR ;
Belliveau, JW ;
Rosen, BR .
HUMAN BRAIN MAPPING, 1995, 3 (01) :13-23
[8]   MONITORING THE PATIENTS EEG DURING ECHO-PLANAR MRI [J].
IVES, JR ;
WARACH, S ;
SCHMITT, F ;
EDELMAN, RR ;
SCHOMER, DL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 87 (06) :417-420
[9]  
KRAKOW K, 1997, ISMRM 6 SCI M SYDN A, P1494
[10]   Recording of electrical brain activity in a magnetic resonance environment:: Distorting effects of the static magnetic field [J].
Müri, RM ;
Felblinger, J ;
Rösler, KM ;
Jung, B ;
Hess, CW ;
Boesch, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) :18-22