In vitro adenosine detection with a diamond-based sensor

被引:50
作者
Xie, ST
Shafer, G
Wilson, CG
Martin, HB
机构
[1] Case Western Reserve Univ, Dept Chem Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Pediat, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
hot filament CVD; diamond film; sensors; biomedical applications;
D O I
10.1016/j.diamond.2005.08.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Diamond-based electrodes promise major advantages over present electrode technologies used in biomedical research. To demonstrate these advantages, boron-doped diamond microelectrodes were developed for in vitro detection of adenosine, an important neuromodulator in the central nervous system. Diamond was selectively deposited as part of a unique fabrication strategy to obtain non-planar, needle-like diamond microelectrodes. Preliminary flow injection analysis showed quantified adenosine down to 10 nM, a lower level than the estimated basal adenosine level in vivo, and lower than what is achieved on other electrode materials. As an example of in vitro application, the diamond probe was used to investigate the role of adenosine in respiratory rhythmogenesis (i.e., the modulation of one's breathing rate). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 228
页数:4
相关论文
共 11 条
[1]   PHARMACOKINETIC ASPECTS OF THEOPHYLLINE IN PREMATURE NEWBORNS [J].
ARANDA, JV ;
SITAR, DS ;
PARSONS, WD ;
LOUGHNAN, PM ;
NEIMS, AH .
NEW ENGLAND JOURNAL OF MEDICINE, 1976, 295 (08) :413-416
[2]   The role and regulation of adenosine in the central nervous system [J].
Dunwiddie, TV ;
Masino, SA .
ANNUAL REVIEW OF NEUROSCIENCE, 2001, 24 :31-55
[3]  
ELNOUR KA, 2001, ELECTROANAL, V12, P805
[4]   FAST-SCAN CYCLIC VOLTAMMETRY OF 5-HYDROXYTRYPTAMINE [J].
JACKSON, BP ;
DIETZ, SM ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1115-1120
[5]   Neuronal pacemaker for breathing visualized in vitro [J].
Koshiya, N ;
Smith, JC .
NATURE, 1999, 400 (6742) :360-363
[6]  
MARTIN HB, 1996, J ELECTROCHEM SOC, V143, P133
[7]   Color images for fast-scan CV [J].
Michael, D ;
Travis, ER ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 1998, 70 (17) :586A-592A
[8]   Improving data acquisition for fast scan cyclic voltammetry [J].
Michael, DJ ;
Joseph, JD ;
Kilpatrick, MR ;
Travis, ER ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :3941-3947
[9]   Prebotzinger complex and pacemaker neurons: Hypothesized site and kernel for respiratory rhythm generation [J].
Rekling, JC ;
Feldman, JL .
ANNUAL REVIEW OF PHYSIOLOGY, 1998, 60 :385-405
[10]   PRE-BOTZINGER COMPLEX - A BRAIN-STEM REGION THAT MAY GENERATE RESPIRATORY RHYTHM IN MAMMALS [J].
SMITH, JC ;
ELLENBERGER, HH ;
BALLANYI, K ;
RICHTER, DW ;
FELDMAN, JL .
SCIENCE, 1991, 254 (5032) :726-729