A new technique for complex fibula fracture fixation in the elderly: A clinical and biomechanical evaluation

被引:48
作者
Koval, KJ
Petraco, DM
Kummer, FJ
Bharam, S
机构
[1] Department of Orthopaedic Surgery, Hosp. for Jt. Dis. Orthoped. Inst., New York, NY
[2] Department of Orthopaedic Surgery, Hosp. for Jt. Dis. Orthoped. Inst., New York, NY 10003
关键词
fibula fracture; internal fixation; clinical; biomechanical;
D O I
10.1097/00005131-199701000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To determine whether intramedullary fixation could augment plate fixation strength in comminuted and osteopenic fibula fractures. Study Design: Retrospective clinical study and biomechanical laboratory study. Methods:Twenty comminuted or osteopenic fibula fractures in twenty patients age fifty years or older were stabilized using plate fixation augmented with intramedullary Kirschner wires. Nineteen patients were available for follow-up which averaged 15.4 months (range, 6-43 months). Ln conjunction with this clinical series, a biomechanical evaluation was performed comparing fixation of mildly osteopenic fibulas using this technique to plate and screws alone. The fibulas were first tested non destructively in bending, and then destructively in torsion to determine stability and ultimate strength of the fixation. Results: All nineteen fractures united without loss of reduction: seventeen of nineteen patients (89%) had either no pain, slight or mild pain. Biomechanical testing demonstrated that the resistance to bending of the plated fibulas augmented with Kirschner wires was 81% greater than the fibulas stabilized with a plate alone (p <.05). In torsional testing, the augmented group had twice the resistance to motion than the plate group (p <.002). Conclusion: This clinical series and biomechanical study support the use of plate fixation augmented with intramedullary Kirschner wires for the treatment of comminuted and osteopenic fibula fractures in the elderly.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 23 条
[1]
ANKLE FRACTURES IN THE ELDERLY - MUA VERSUS ORIF [J].
ANAND, N ;
KLENERMAN, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1993, 24 (02) :116-120
[2]
[Anonymous], CLIN ORTHOP
[3]
DISPLACED ANKLE FRACTURES IN PATIENTS OVER 50 YEARS OF AGE [J].
BEAUCHAMP, CG ;
CLAY, NR ;
THEXTON, PW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (03) :329-332
[4]
ANKLE FRACTURES TREATED USING BIODEGRADABLE INTERNAL-FIXATION [J].
BOSTMAN, O ;
HIRVENSALO, E ;
VAINIONPAA, S ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (238) :195-203
[5]
TREATMENT OF UNSTABLE ANKLE FRACTURES [J].
BRODIE, IAOD ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1974, B 56 (02) :256-262
[6]
FRACTURE OF THE LATERAL MALLEOLUS - COMPARISON OF 2 FIXATION METHODS IN CADAVERS [J].
ECKERWALL, G ;
PERSSON, BM .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (05) :595-597
[7]
Evans FG., 1966, Studies on the anatomy and function of bone and joints, P142, DOI DOI 10.1007/978-3-642-99909-3_10
[8]
SURVEY OF 100 CASES OF WHIPLASH INJURY AFTER SETTLEMENT OF LITIGATION [J].
GOTTEN, N .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 162 (09) :865-867
[9]
HEIM U, 1982, SMALL FRAGMENT SET M, P285