A comparison of quantitative nuclear magnetic resonance methods: internal, external, and electronic referencing

被引:54
作者
Cullen, Christopher H. [1 ]
Ray, G. Joseph [1 ]
Szabo, Christina M. [1 ]
机构
[1] Baxter Healthcare Corp, Round Lake, IL 60073 USA
关键词
NMR; H-1; quantitation; purity determination; ERETIC; internal reference; external reference; PROTON NMR; NATURAL-PRODUCTS; ERETIC METHOD; SIGNAL; QUANTIFICATION; SPECTROSCOPY; STANDARDS; H-1-NMR;
D O I
10.1002/mrc.4004
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The performance of three quantitative NMR methods was compared in terms of short-term and long-term precision and accuracy, robustness, linear range, and general applicability. The Internal Reference method employs a reference material co-dissolved with sample; the External Reference method employs a reference material contained in a separate solution; and the third method, known as Electronic REference To access In vivo Concentrations (ERETIC), employs an externally calibrated digital reference peak. The Internal Reference method results were the most precise and remained stable within 0.1% for at least 4weeks. The results from the External Reference and ERETIC methods were practically equivalent to each other during this time. These methods exhibited small differences relative to the standard set by the Internal Reference method and slightly lower precision, establishing them as practical alternatives to the Internal Reference method. In contrast to the Internal Reference method, the External Reference and ERETIC methods possess several advantages that address peak overlap, flexibility of calibration, and duration of applicability. The study was designed such that each spectrum contained the information needed to compare the three methods while all other variables were kept constant. Applicability of pulse width compensation is addressed. ERETIC software compensation and minor adjustments to 90 degrees pulse width were concluded to be unnecessary for this system. Although each of the methods was applied here to specifically calculate and compare chemical purity values, this evaluation applies generally to absolute quantitation by NMR. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:705 / 713
页数:9
相关论文
共 23 条
[1]   Concentration measurement by proton NMR using the ERETIC method [J].
Akoka, S ;
Barantin, L ;
Trierweiler, M .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2554-2557
[2]   A new method for absolute quantitation of MRS metabolites [J].
Barantin, L ;
LePape, A ;
Akoka, S .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :179-182
[3]   Quantitative 1H NMR with external standards:: Use in preparation of calibration solutions for algal toxins and other natural products [J].
Burton, IW ;
Quilliam, MA ;
Walter, JA .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3123-3131
[4]   Determination of metabolite concentrations in human brain tumour biopsy samples using HR-MAS and ERETIC measurements [J].
Carmen Martinez-Bisbal, M. ;
Monleon, Daniel ;
Assemat, Olivier ;
Piotto, Martial ;
Piquer, Jose ;
Luis Llacer, Jose ;
Celda, Bernardo .
NMR IN BIOMEDICINE, 2009, 22 (02) :199-206
[5]   Quantitative metabolic profiles of 2nd and 3rd trimester human amniotic fluid using 1H HR-MAS spectroscopy [J].
Cohn, Brad R. ;
Joe, Bonnie N. ;
Zhao, Shoujun ;
Kornak, John ;
Zhang, Vickie Y. ;
Iman, Rahwa ;
Kurhanewicz, John ;
Vahidi, Kiarash ;
Yu, Jingwei ;
Caughey, Aaron B. ;
Swanson, Mark G. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2009, 22 (06) :343-352
[6]   NMR quantification using an artificial signal [J].
Farrant, Roger D. ;
Hollerton, John C. ;
Lynn, Sean M. ;
Provera, Stefano ;
Sidebottom, Philip J. ;
Upton, Richard J. .
MAGNETIC RESONANCE IN CHEMISTRY, 2010, 48 (10) :753-762
[7]  
Freeman R., 1998, HDB NUCL MAGNETIC RE, P251
[8]   ANALYSIS OF ORGANOPHOSPHORUS INSECTICIDE AND FORMULATIONS FOR CONTAMINANTS BY P-31 FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE SPECTROMETRY [J].
GREENHALGH, R ;
SHOOLERY, JN .
ANALYTICAL CHEMISTRY, 1978, 50 (14) :2039-2042
[9]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[10]   Toward single-calibrant quantification in HPLC. A comparison of three detection strategies: Evaporative light scattering, chemiluminescent nitrogen, and proton NMR [J].
Lane, S ;
Boughtflower, B ;
Mutton, I ;
Paterson, C ;
Farrant, D ;
Taylor, N ;
Blaxill, Z ;
Carmody, C ;
Borman, P .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4354-4365