Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 tesla

被引:187
作者
Van de Moortele, PF
Pfeuffer, J
Glover, GH
Ugurbil, K
Hu, XP
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Sch Med, Dept Radiol, Minneapolis, MN 55455 USA
[2] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
physiological artifacts; respiration artifacts; echoplanar imaging; B-0; fluctuation; off-resonance;
D O I
10.1002/mrm.10145
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In functional magnetic resonance imaging (WRI), it is known that physiological influences such as cardiac pulsation, respiration, and brain motion can induce fluctuations in signal intensity and phase. Some of the mechanisms potentially involved in those phenomena are expected to be amplified at higher magnetic fields. This study addresses the issue of Bo fluctuations induced by susceptibility changes during respiration attributed to movements of chest and diaphragm, and variations in the oxygen concentration. It is demonstrated that respiration-induced resonance offsets (RIROs) are significant at 7T. Data were acquired with an RF pulse (no gradients), multislice echoplanar imaging (EPI), and dynamic 3D fast low-angle shot (3D-FLASH) imaging. Three main observations summarize the experimental findings. First, in FIDs measured after a single RIF pulse, a RIRO with a large amplitude was consistently detected, although the average amplitude varied between subjects from 1.45 Hz to 4 Hz. Second, in transverse EPI images obtained in the occipital lobe, the RIRO amplitude showed a monotonic Increase along the z axis toward the lungs. Third, a more detailed spatial analysis with 3D-FLASH phase maps revealed that a previously published analytical model can accurately describe the spatial distribution of RIRO. Consequential apparent motions in the EPI series, as well as the implications of slice orientation for correction strategies are discussed. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:888 / 895
页数:8
相关论文
共 31 条
[1]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
[2]   Noise suppression digital filter for functional magnetic resonance imaging based on image reference data [J].
Buonocore, MH ;
Maddock, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :456-469
[3]   IMPACT: Image-based physiological artifacts estimation and correction technique for functional MRI [J].
Chuang, KH ;
Chen, JH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :344-353
[4]   Artifact due to Bo fluctuations in fMRI:: Correction using the k-space central line [J].
Durand, E ;
van de Moortele, PF ;
Pachot-Clouard, M ;
Le Bihan, D .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :198-201
[5]   Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data [J].
Frank, LR ;
Buxton, RB ;
Wong, EC .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :635-644
[6]  
Glover GH, 2000, MAGNET RESON MED, V44, P162, DOI 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO
[7]  
2-E
[8]  
Gruetter R, 2000, MAGNET RESON MED, V43, P319, DOI 10.1002/(SICI)1522-2594(200002)43:2<319::AID-MRM22>3.0.CO
[9]  
2-1
[10]  
Henry PG, 1999, MAGN RESON MED, V42, P636, DOI 10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO