Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements - Factors affecting survivorship of acetabular and femoral components

被引:517
作者
Berry, DJ [1 ]
Harmsen, WS [1 ]
Cabanela, ME [1 ]
Morrey, BF [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
D O I
10.2106/00004623-200202000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Charnley total hip arthroplasty has been demonstrated to provide good clinical results and a high rate of implant survivorship for twenty years and longer, Most long-term series are not large enough to stratify the many demographic factors that influence implant survivorship. The purpose of this study was to analyze the effects of demographic factors and diagnoses on the long-term survivorship of the acetabular and femoral components used in Charnley total hip arthroplasty. Methods. Two thousand primary Charnley total hip arthroplasties (1689 patients) were performed at one institution from 1969 to 1971. Patients were contacted at five-year intervals after the arthroplasty. Twenty-five years after the surgery, 1228 patients had died and 461 patients were living. Hips that had not had a reoperation, revision or removal of a component for any reason, or revision or removal for aseptic loosening were considered to have survived. Survivorship data were calculated with use of the method of Kaplan and Meier. Patients were stratified by age, gender, and underlying diagnosis to determine the influence of these factors on implant survivorship. Results: The twenty-five year rates of survivorship free of reoperation, free of revision or removal of the implant for any reason, and free of revision or removal for aseptic loosening were 77.5%, 80.9% and 86.5%, respectively. The twenty-five-year survivorship free of revision for aseptic loosening was poorer for each decade earlier in life at which the procedure was performed; this survivorship ranged from 68.7% for patients who were less than forty years of age to 100% for patients who were eighty years of age or older. Men had a twofold higher rate of revision for aseptic loosening than did women. Conclusions: Age, gender, and underlying diagnosis all affected the likelihood of long-term survivorship of the acetabular and femoral components used in Charnley total hip arthroplasty.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 37 条
[1]
SIMPLE PARAMETRIC AND NONPARAMETRIC MODELS FOR EXCESS AND RELATIVE MORTALITY [J].
ANDERSEN, PK ;
VAETH, M .
BIOMETRICS, 1989, 45 (02) :523-535
[2]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[3]
TOTAL HIP ARTHROPLASTY - REVIEW OF 333 CASES WITH LONG FOLLOW-UP [J].
BECKENBAUGH, RD ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :306-313
[4]
BRADY LP, 1986, CLIN ORTHOP RELAT R, P51
[5]
Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[6]
Charnley total hip arthroplasty in patients less than fifty years old - A twenty to twenty-five-year follow-up note [J].
Callaghan, JJ ;
Forest, EE ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :704-714
[7]
TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434
[8]
COLLIS DK, 1988, ORTHOP CLIN N AM, V19, P541
[9]
[10]
Total hip arthroplasty with cement in patients who have rheumatoid arthritis - A minimum ten-year follow-up study [J].
Creighton, MG ;
Callaghan, JJ ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1439-1446