Comparison of Three Different Techniques of Corneal Transplantation for Keratoconus

被引:133
作者
Bahar, Irit [1 ]
Kaiserman, Igor [1 ]
Srinivasan, Sathish [1 ,2 ]
Ya-Ping, Jin [1 ]
Slomovic, Allan R. [1 ]
Rootman, David S. [1 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Ophthalmol, Univ Hlth Network, Toronto, ON M5T 2S8, Canada
[2] Ayr Hosp, Dept Ophthalmol, Ayr, Scotland
关键词
D O I
10.1016/j.ajo.2008.06.034
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual outcomes following deep anterior lamellar keratoplasty (DALK), penetrating keratoplasty (PK), and manual top,hat PK (TH-PK) in subjects undergoing corneal transplantation for keratoconus (KC). DESIGN: A retrospective comparative case series. METHODS: SETTINGS: Cornea clinic at the Toronto Western Hospital. STUDY POPULATION: Fifty patients who underwent corneal transplantation for KC: 17 eyes underwent DALK, 20 eyes underwent traditional PK, and 13 had TH-PK. MAIN OUTCOME MEASURES: Preoperative and postoperative uncorrected and best spectacle-corrected visual acuity (UCVA, BSCVA), high order aberrations (HOA), complication rate, and endothelial cell counts. RESULTS: The median BSCVA at 12 months follow,up was 20/40 in the DALK eyes and 20/30 in the traditional PK and TH-PK eyes. The mean final spherical equivalent power in the three groups was less than -1 diopter (D). The median astigmatism was less than 3.5 D in the three groups. Complication rates were similar for three groups, although the DALK group tended toward more complications. Although DALK and TH-PK procedure results in significantly shorter time to suture removal (P < .01), they caused increased levels of HOAs (P = .02). Endothelial cell counts at 12 months were significantly higher in DALK and TH-PK eyes when compared to the traditional PK eyes (P < .001). CONCLUSIONS: DALK, PK, and TH-PK provide comparable visual outcomes in keratoconus patients. Although DALK and TH-PK induce more HOA, they speed up the time to suture removal and provide higher endothelial cell density at one year of follow-up. (Am J Ophthalmol 2008;146:905-912. (C) 2008 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:905 / 912
页数:8
相关论文
共 26 条
[1]   Fluid lamellar keratoplasty in keratoconus [J].
Amayem, AF ;
Anwar, M .
OPHTHALMOLOGY, 2000, 107 (01) :76-79
[2]   Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty [J].
Anwar, M ;
Teichmann, KD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03) :398-403
[3]  
Archila E A, 1984, Cornea, V3, P217
[4]   Quality of vision and graft thickness in deep anterior lamellar and penetrating corneal allografts [J].
Ardiomand, Navid ;
Hau, Scott ;
McAlister, James C. ;
Bunce, Catey ;
Galaretta, David ;
Tuft, Stephen J. ;
Larkin, Daniel F. P. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) :228-235
[5]   Manual top hat wound configuration for penetrating keratoplasty [J].
Bahar, Irit ;
Kaiserman, Igor ;
Srinivasan, Sathish ;
Berger, Yoav ;
McAllum, Penny ;
Slomovic, Allan ;
Rootman, David .
CORNEA, 2008, 27 (05) :521-526
[6]   Penetrating keratoplasty for keratoconus [J].
Brierly, SC ;
Izquierdo, L ;
Mannis, MJ .
CORNEA, 2000, 19 (03) :329-332
[7]   The use of the femtosecond laser in penetrating keratoplasty [J].
Buratto, Lucio ;
Bohm, Elisabetta .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (05) :737-742
[8]  
Busin M, 2003, ARCH OPHTHALMOL-CHIC, V121, P260
[9]   DEEP LAMELLAR KERATOPLASTY ON AIR WITH LYOPHILIZED TISSUE [J].
CHAU, GK ;
DILLY, SA ;
SHEARD, CE ;
ROSTRON, CK .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (11) :646-650
[10]   Estimating visual quality from wavefront aberration measurements [J].
Cheng, X ;
Thibos, LN ;
Bradley, A .
JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (05) :S579-S584