Hemodynamic collapse during off-pump coronary artery bypass grafting

被引:62
作者
Vassiliades, TA [1 ]
Nielsen, JL [1 ]
Lonquist, JL [1 ]
机构
[1] Pensacola Heart Inst, Pensacola, FL USA
关键词
D O I
10.1016/S0003-4975(02)03592-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The causes of hemodynamic collapse during off-pump coronary artery bypass (OPCAB) remain scarcely defined. We present an analysis of 23 cases of sustained hemodynamic collapse during elective off-pump CABG. Methods. During a 54-month period, we performed 1420 elective OPCAB procedures through a sternotomy, constituting 71.2% of the total CABG procedures performed. Twenty-three patients (1.6%) experienced hemodynamic collapse intra-operatively requiring immediate cardiopulmonary bypass. Preoperative characteristics, intraoperative data, and postoperative outcome were retrospectively reviewed in each patient. Results. In all cases, improvements in intra-operative technique and/or judgment could be made retrospectively. Twenty (20/23) of these patients had an uneventful postoperative course and three (3/23) patients had an unstable course with two deaths. Conclusions. The causes of hemodynamic collapse during elective OPCAB were ischemic, mechanical, or a combination of both. A detailed review of our five and a half year experience has revealed a number of suggestions for improving the conduct of the operation.
引用
收藏
页码:1874 / 1879
页数:6
相关论文
共 23 条
  • [1] Safety and efficacy of off-pump coronary artery bypass grafting
    Arom, KV
    Flavin, TF
    Emery, RW
    Kshettry, VR
    Janey, PA
    Petersen, RJ
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (03) : 704 - 710
  • [2] Technical aspects of total revascularization in off-pump coronary bypass via sternotomy approach
    Baumgartner, FJ
    Gheissari, A
    Capouya, ER
    Panagiotides, GP
    Katouzian, A
    Yokoyama, T
    [J]. ANNALS OF THORACIC SURGERY, 1999, 67 (06) : 1653 - 1658
  • [3] Bedi HS, 2000, ANN THORAC SURG, V69, P156
  • [4] Myocardial revascularization with and without cardiopulmonary bypass in multivessel disease: Impact of the strategy on early outcome
    Calafiore, AM
    Di Mauro, M
    Contini, M
    Di Giammarco, G
    Pano, M
    Vitolla, G
    Bivona, A
    Carella, R
    D'Alessandro, S
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (02) : 456 - 462
  • [5] Current results in off pump surgery
    Contini, M
    Iacò, A
    Iovino, T
    Teodori, G
    Di Giammarco, G
    Mazzei, V
    Commodo, M
    Calafiore, AM
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 : S69 - S72
  • [6] Off-pump bypass grafting is safe in patients with left main coronary disease
    Dewey, TM
    Magee, MJ
    Edgerton, JR
    Mathison, M
    Tennison, D
    Mack, MJ
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (03) : 788 - 791
  • [7] Dullum MKC, 2000, HEART SURG FORUM, V3, P113
  • [8] Perfusion-assisted direct coronary artery bypass: Selective graft perfusion in off-pump cases
    Guyton, RA
    Thourani, VH
    Puskas, JD
    Shanewise, JS
    Steele, MA
    Palmer-Steele, CL
    Vinten-Johansen, J
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (01) : 171 - 175
  • [9] Hirose H, 1999, Ann Thorac Cardiovasc Surg, V5, P304
  • [10] Off or on bypass:: What is the safety threshold?
    Iacò, AL
    Contini, M
    Teodori, G
    Di Mauro, M
    Di Giammarco, G
    Vitolla, G
    Iovino, T
    Calafiore, AM
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (04) : 1486 - 1489