An in vitro investigation of plasma sprayed hydroxyapatite (HA) coatings produced with flame-spheroidized feedstock

被引:123
作者
Kweh, SWK
Khor, KA
Cheang, P
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Mat Engn, Singapore 639798, Singapore
关键词
hydroxyapatite coatings; calcium phosphate; plasma spraying; dissolution; precipitation; simulated body fluid;
D O I
10.1016/S0142-9612(01)00183-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The in vitro behaviour and characteristics of plasma sprayed hydroxyapatite (HA) coatings using flame-spheroidized HA feedstock powder on titanium alloy (Ti-6Al-4V) substrates were investigated in a simulated physiological environment as an attempt to reflect the actual incubational condition of an implant in a human body system. As-sprayed and heat-treated HA coatings were immersed in a simulated body fluid with ionic concentrations comparable to that of human blood plasma for time intervals 2, 4 6, 8 and 10 weeks. Rapid dissolution of calcium phosphate was found to occur within the first 4 weeks, and after the 5th week a retarding rate of 4.1 mm week(-1) was observed where precipitation, nucleation, and, growth of a carbonate-containing, poorly crystallized or amorphous calcium phosphate layer on the as-sprayed coatings were noted. The heat-treated coatings showed minimal or no precipitation on the surface except for the presence of calcite minerals that is due to carbonation effect. Complete dissolution of other calcium phosphate phases Such as tetracalcium phosphate, tricalcium phosphate and calcium oxide was also noted after 2 weeks of immersion due to higher ionic solubility relative to HA. A declining trend in respective microhardness and elastic modulus of the as-sprayed HA coatings from 2207.06 +/-3.2H(k300) to 131.8 +/-5.2H(k300) and from 31.37 +/-1.4 to 19.81 +/-1.6 GPa was observed after 10 weeks of immersion. Tensile bond strength of both types of coatings showed similar declining trend, with an average dip from 24.5 +/-2.4 to 7.9 +/-2.6 MPa. Nevertheless. the heat-treated samples showed rather reasonable mechanical stability and structural integrity of 26.7 +/-1.4 GPa in elastic modulus after soaking. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:775 / 785
页数:11
相关论文
共 34 条
[1]
Water vapour-treated hydroxyapatite coatings after plasma spraying and their characteristics [J].
Cao, Y ;
Weng, J ;
Chen, JY ;
Feng, JM ;
Yang, ZJ ;
Zhang, XD .
BIOMATERIALS, 1996, 17 (04) :419-424
[2]
Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium .2. Dissolution behaviour in simulated body fluid and bonding degradation [J].
Chang, E ;
Chang, WJ ;
Wang, BC ;
Yang, CY .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (04) :201-211
[3]
CHEANG P, 1995, P ITSC 95, P181
[4]
Dissolution behaviour of calcium phosphate coatings obtained by laser ablation [J].
Clèries, L ;
Fernández-Pradas, JM ;
Sardin, G ;
Morenza, JL .
BIOMATERIALS, 1998, 19 (16) :1483-1487
[5]
THE EFFECT OF CALCIUM-PHOSPHATE CERAMIC COMPOSITION AND STRUCTURE ON INVITRO BEHAVIOR .1. DISSOLUTION [J].
DUCHEYNE, P ;
RADIN, S ;
KING, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (01) :25-34
[6]
IN-VITRO TESTING OF PLASMA-SPRAYED HYDROXYAPATITE COATINGS [J].
GROSS, KA ;
BERNDT, CC .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (04) :219-224
[7]
Gross KA, 1997, INT J ORAL MAX IMPL, V12, P589
[8]
Ha SW, 1998, J AM CERAM SOC, V81, P81
[9]
Heimann RB, 1998, J BIOMED MATER RES, V43, P441, DOI 10.1002/(SICI)1097-4636(199824)43:4<441::AID-JBM12>3.3.CO
[10]
2-N