Metabolic profiling of serum using Ultra Performance Liquid Chromatography and the LTQ-Orbitrap mass spectrometry system

被引:152
作者
Dunn, Warwick B. [1 ]
Broadhurst, David [2 ]
Brown, Marie [2 ]
Baker, Philip N. [3 ]
Redman, Christopher W. G. [4 ]
Kenny, Louise C. [3 ,5 ]
Kell, Douglas B. [1 ,2 ]
机构
[1] Univ Manchester, Manchester Interdisciplinary Bioctr, Sch Chem, Manchester Ctr Integrat Syst Biol, Manchester M1 7DN, Lancs, England
[2] Univ Manchester, Manchester Interdisciplinary Bioctr, Sch Chem, Bioanalyt Sci Grp, Manchester M1 7DN, Lancs, England
[3] Univ Manchester, St Marys Hosp, Maternal & Fetal Hlth Res Ctr, Manchester M13 0JH, Lancs, England
[4] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Obstet & Gynaecol, Oxford OX3 9DU, England
[5] Natl Univ Ireland Univ Coll Cork, Cork Univ Matern Hosp, Dept Obstet & Gynaecol, Cork, Ireland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 871卷 / 02期
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
UPLC; Orbitrap; XCMS; metabolic profiling; UPLC-MS; pre-eclampsia;
D O I
10.1016/j.jchromb.2008.03.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Advances in analytical instrumentation can provide significant advantages to the volume and quality of biological knowledge acquired in metabolomic investigations. The interfacing of sub-2 mu m liquid chromatography (UPLC ACQUITY (R)) and LTQ-Orbitrap mass spectrometry systems provides many theoretical advantages. The applicability of the interfaced systems was investigated using a simple 11-component metabolite mix and a complex mammalian biofluid, serum. Metabolites were detected in the metabolite mix with signals that were linear with their concentration over 2.5-3.5 orders of magnitude, with correlation coefficients greater than 0.993 and limits of detection less than 1 mu mol L-1. Reproducibility of retention time (RSD < 3%) and chromatographic peak area (RSD < 15%) and a high mass accuracy (<2 ppm) were observed for 14 QC serum samples interdispersed with other serum samples, analysed over a period of 40 h. The evaluation of a single deconvolution software package (XCMS) was performed and showed that two parameters (snthresh and bw) provided significant changes to the number of peaks detected and the peak area reproducibility for the dataset used. The data were used to indicate possible biomarkers of pre-eclampsia and showed both the instruments and XCMS to be applicable to the reproducible and valid detection of disease biomarkers present in serum. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:288 / 298
页数:11
相关论文
共 92 条
[1]   Analysis of organic acid markers relevant to inherited metabolic diseases by ultra-performance liquid chromatography/tandem mass spectrometry as benzofurazan derivatives [J].
Al-Dirbashi, Osama Y. ;
Santa, Tomofumi ;
Al-Qahtani, Khalid ;
Al-Amoudi, Mohammed ;
Rashed, Mohamed S. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (13) :1984-1990
[2]   Metabolomic approaches reveal that phosphatidic and phosphatidyl glycerol phospholipids are major discriminatory non-polar metabolites in responses by Brachypodium distachyon to challenge by Magnaporthe grisea [J].
Allwood, JW ;
Ellis, DI ;
Heald, JK ;
Goodacre, R ;
Mur, LAJ .
PLANT JOURNAL, 2006, 46 (03) :351-368
[3]   A combined 1H-NMR spectroscopy- and mass spectrometry-based metabolomic study of the PPAR-α null mutant mouse defines profound systemic changes in metabolism linked to the metabolic syndrome [J].
Atherton, Helen J. ;
Bailey, Nigel J. ;
Zhang, Wen ;
Taylor, John ;
Major, Hilary ;
Shockcor, John ;
Clarke, Kieran ;
Griffin, Julian L. .
PHYSIOLOGICAL GENOMICS, 2006, 27 (02) :178-186
[4]  
BAKER PN, REPROD SCI IN PRESS
[5]   MathDAMP: a package for differential analysis of metabolite profiles [J].
Baran, Richard ;
Kochi, Hayataro ;
Saito, Natsumi ;
Suematsu, Makoto ;
Soga, Tomoyoshi ;
Nishioka, Takaaki ;
Robert, Martin ;
Tomita, Masaru .
BMC BIOINFORMATICS, 2006, 7 (1)
[6]   The light-hyperresponsive high pigment-2dg mutation of tomato:: alterations in the fruit metabolome [J].
Bino, RJ ;
de Vos, CHR ;
Lieberman, M ;
Hall, RD ;
Bovy, A ;
Jonker, HH ;
Tikunov, Y ;
Lommen, A ;
Moco, S ;
Levin, I .
NEW PHYTOLOGIST, 2005, 166 (02) :427-438
[7]   Precision mapping of the metabolome [J].
Breitling, Rainer ;
Pitt, Andrew R. ;
Barrett, Michael P. .
TRENDS IN BIOTECHNOLOGY, 2006, 24 (12) :543-548
[8]   Statistical strategies for avoiding false discoveries in metabolomics and related experiments [J].
Broadhurst, David I. ;
Kell, Douglas B. .
METABOLOMICS, 2006, 2 (04) :171-196
[9]   MET-IDEA: Data extraction tool for mass spectrometry-based metabolomics [J].
Broeckling, Corey D. ;
Reddy, Indira R. ;
Duran, Anthony L. ;
Zhao, Xuechun ;
Sumner, Lloyd W. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4334-4341
[10]  
CASTRILLO JI, 2007, J BIOL LONDON, V6, pNIL6