High-precision measurement of mercury isotope ratios in sediments using cold-vapor generation multi-collector inductively coupled plasma mass spectrometry

被引:147
作者
Foucher, D [1 ]
Hintelmann, H [1 ]
机构
[1] Trent Univ, Dept Chem, Peterborough, ON K9J 7B8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
mercury; stable isotopes; isotope ratios; multi-collector ICP; MS; fractionation; sediments;
D O I
10.1007/s00216-006-0373-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-line Hg reduction technique using stannous chloride as the reductant was applied for accurate and precise mercury isotope ratio determinations by multi-collector (MC)-ICP/MS. Special attention has been paid to ensure optimal conditions (such as acquisition time and mercury concentration) allowing precision measurements good enough to be able to significantly detect the anticipated small differences in Hg isotope ratios in nature. Typically, internal precision was better than 0.002% (1 RSE) on all Hg ratios investigated as long as approximately 20 ng of Hg was measured with a 10-min acquisition time. Introducing higher amounts of mercury (50 ng Hg) improved the internal precision to < 0.001%. Instrumental mass bias was corrected using Tl-205/Tl-203 correction coupled to a standard-sample bracketing approach. The large number of data acquired allowed us to validate the consistency of our measurements over a one-year period. On average, the short-term uncertainty determined by repeated runs of NIST SRM 1641d Hg standard during a single day was < 0.006% (1 RSD) for all isotope pairs investigated (Hg-202/Hg-198, Hg-202/Hg-199, Hg-202/Hg-200, and Hg-202/Hg-201). The precision fell to < 0.01% if the long-term reproducibility, taken over 11 months ( over 100 measurements), was considered. The extent of fractionation has been investigated in a series of sediments subject to various Hg sources from different locations worldwide. The ratio Hg-202/Hg-198 expressed as delta values ( per mil deviations relative to NIST SRM 1641d Hg standard solution) displayed differences from + 0.74 to - 4.00 parts per thousand. The magnitude of the Hg fractionation per amu was constant within one type of sample and did not exceed 1.00 parts per thousand. Considering all results ( the reproducibility of Hg standard solutions, reference sediment samples, and the examination of natural samples), the analytical error of our delta values for the overall method was within +/- 0.28 parts per thousand( 1 SD), which was an order of magnitude lower than the extent of fractionation (4.74 parts per thousand) observed in sediments. This study confirmed that analytical techniques have reached a level of long-term precision and accuracy that is sufficiently sensitive to detect even small differences in Hg isotope ratios that occur within one type of samples (e.g., between different sediments) and so far have unequivocally shown that Hg isotope ratios in sediments vary within approximately 5 parts per thousand..
引用
收藏
页码:1470 / 1478
页数:9
相关论文
共 22 条
[1]   Development of isotope dilution cold vapor inductively coupled plasma mass spectrometry and its application to the certification of mercury in NIST standard reference materials [J].
Christopher, SJ ;
Long, SE ;
Rearick, MS ;
Fassett, JD .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2190-2199
[2]  
Donard OFX, 2003, GEOCHIM COSMOCHIM AC, V67, pA81
[3]   Measurement of high precision isotope ratios for mercury from coals using transient signals [J].
Evans, RD ;
Hintelmann, H ;
Dillon, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :1064-1069
[4]   Measurement of isotope ratios on transient signals by MC-ICP-MS [J].
Günther-Leopold, I ;
Wernli, B ;
Kopajtic, Z ;
Günther, D .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :241-249
[5]   Applications of multiple collector-ICPMS to cosmochemistry, geochemistry, and paleoceanography [J].
Halliday, AN ;
Lee, DC ;
Christensen, JN ;
Rehkamper, M ;
Yi, W ;
Luo, XZ ;
Hall, CM ;
Ballentine, CJ ;
Pettke, T ;
Stirling, C .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (06) :919-940
[6]   High precision isotope ratio measurements of mercury isotopes in cinnabar ores using multi-collector inductively coupled plasma mass spectrometry [J].
Hintelmann, H ;
Lu, SY .
ANALYST, 2003, 128 (06) :635-639
[7]   Comment: Variations in the isotope composition of mercury in a freshwater sediment sequence and food web [J].
Hintelmann, H ;
Dillon, P ;
Evans, RD ;
Rudd, JWM ;
Bodaly, RA .
CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 2001, 58 (11) :2309-2311
[8]   Historical variations in the stable isotope composition of mercury in Arctic lake sediments [J].
Jackson, TA ;
Muir, DCG ;
Vincent, WF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (10) :2813-2821
[9]   Variations in the isotope composition of mercury in a freshwater sediment sequence and food web [J].
Jackson, TA .
CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 2001, 58 (01) :185-196
[10]   Trace analyses of arsenic in drinking water by inductively coupled plasma mass spectrometry: High resolution versus hydride generation [J].
Klaue, B ;
Blum, JD .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1408-1414