An investigation of the validity of attachment level measurements with an automated periodontal probe

被引:9
作者
Ahmed, N [1 ]
Watts, TLP [1 ]
Wilson, RF [1 ]
机构
[1] UMDS,DEPT PERIODONTOL & PREVENT DENT,LONDON,ENGLAND
关键词
periodontal probe; validity; periodontal diseases; periodontal pocket; attachment level;
D O I
10.1111/j.1600-051X.1996.tb00573.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
There is a need for information on the validity of probing depth and attachment level measurements made with automated probes. In this study, 34 teeth in 9 patients were measured with the Florida probe from points marked with a bur prior to extraction. After extraction, connective tissue attachment levels were measured from the same points with a dissecting microscope. Mean measurements of attachment level were similar with probing (5.13+/-2.08 mm) and laboratory (5.18+/-2.26 mm) assessments. The correlation between these measurements was 0.72 (p<0.001), and a t-test of the paired measurements showed no difference (t=0.44; p=0.66). The Florida probe thus showed satisfactory validity for this group of measurements of advanced periodontitis. However, there was substantial lack of agreement between individual probing measurements and the validity criterion of laboratory attachment level measurements, and the intra-class correlation coefficient was 0.46. It was concluded that the Florida probe was suitable for studies in which measurements were averaged, but not for longitudinal study of individual sites.
引用
收藏
页码:452 / 455
页数:4
相关论文
共 19 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   MEASURING CLINICAL ATTACHMENT - REPRODUCIBILITY OF RELATIVE MEASUREMENTS WITH AN ELECTRONIC PROBE [J].
CLARK, WB ;
YANG, MCK ;
MAGNUSSON, I .
JOURNAL OF PERIODONTOLOGY, 1992, 63 (10) :831-838
[3]  
GABATHULER H, 1971, HELV ODONTOL ACTA, V15, P114
[4]  
GHASSEMIAVAL A, 1994, J DENT RES, V73, P116
[5]   DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE [J].
GIBBS, CH ;
HIRSCHFELD, JW ;
LEE, JG ;
LOW, SB ;
MAGNUSSON, I ;
THOUSAND, RR ;
YERNENI, P ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) :137-144
[6]   PERIODONTAL PROBING - WHAT DOES IT MEAN [J].
LISTGARTEN, MA .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1980, 7 (03) :165-176
[7]   CORRELATION BETWEEN ELECTRONIC AND VISUAL READINGS OF POCKET DEPTHS WITH A NEWLY DEVELOPED CONSTANT FORCE PROBE [J].
MAGNUSSON, I ;
FULLER, WW ;
HEINS, PJ ;
RAU, CF ;
GIBBS, CH ;
MARKS, RG ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :180-184
[8]   ATTACHMENT LEVEL MEASUREMENTS WITH A CONSTANT FORCE ELECTRONIC PROBE [J].
MAGNUSSON, I ;
CLARK, WB ;
MARKS, RG ;
GIBBS, CH ;
MANOUCHEHRPOUR, M ;
LOW, SB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :185-188
[9]   REPRODUCIBILITY OF ATTACHMENT LEVEL MEASUREMENTS WITH 2 MODELS OF THE FLORIDA PROBE [J].
MARKS, RG ;
LOW, SB ;
TAYLOR, M ;
BAGGS, R ;
MAGNUSSON, I ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (10) :780-784
[10]  
PARAKKAL PF, 1979, J DENT RES, V58, P547