Ozone column retrieval from solar UV measurements at ground level:: Effects of clouds and results from six European sites -: art. no. D24202

被引:17
作者
Brogniez, C [1 ]
Houët, M
Siani, AM
Weihs, P
Allaart, M
Lenoble, J
Cabot, T
de la Casinière, A
Kyrö, E
机构
[1] Univ Sci & Technol Lille, CNRS, Opt Atmospher Lab, F-59655 Villeneuve Dascq, France
[2] Univ Roma La Sapienza, Dept Phys, I-00185 Rome, Italy
[3] Agr Univ Vienna, Inst Meteorol & Phys, A-1190 Vienna, Austria
[4] Royal Netherlands Meteorol Inst, NL-3730 De Bilt, Netherlands
[5] Univ Grenoble 1, F-38000 Grenoble, France
[6] Finnish Meteorol Inst, Arctic Res Ctr, FIN-99600 Sodankyla, Finland
关键词
D O I
10.1029/2005JD005992
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
A differential absorption method, developed by the Laboratoire d'Optique Atmospherique (LOA), is applied to retrieve the total ozone column from UV global irradiance spectra under clear and cloudy sky conditions. Contrarily to clear sky, cloudy sky generates a high uncertainty in the retrieved ozone column. This study shows that under cloudy conditions the daily ozone mean is a rather good estimation of the true value. The standard deviation allows us to estimate the relative uncertainty of this mean value, i.e., about 7%. Results for all conditions from 3 years at Villeneuve d'Ascq are presented, as well as a comparison with TOMS (Total Ozone Mapping Spectrometer) data. The results are very similar to those obtained for clear days: In 75% of cases both values agree to within 5%; however, some cases present larger relative differences. Over the 3 years considered, there is a bias less than 3% (LOA>TOMS). This method is applied to five other European sites involved in the EDUCE (European Database for UV Climatology and Evaluation) project. Three of them are Brewer stations. The results of the comparison between the LOA-retrieved ozone and TOMS data show that a relative difference smaller than 5% is obtained in 63-80% of the cases, depending on site and year. Biases smaller than 3% are observed (LOA>TOMS). The comparison between the LOA-retrieved ozone and total ozone data from direct sun and zenith sky observations of the Brewer instruments shows better agreement. For more than about 80% of cases, except at one site, the relative difference is smaller than 5%, and the biases are smaller than 1%. The LOA method allows us to obtain a complementary data set and hence to provide time series of reliable measurements of total ozone column under all sky conditions.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 18 条
[1]   Real-time UV and column ozone from multi-channel UV radiometers deployed in the National Science Foundation's UV monitoring network [J].
Bernhard, G ;
Booth, CR ;
Ehramjian, JC .
ULTRAVIOLET GROUND- AND SPACE-BASED MEASUREMENTS, MODELS AND EFFECTS III, 2003, 5156 :167-178
[2]   Measurements of biologically effective UV doses, total ozone abundances, and cloud effects with multichannel, moderate bandwidth filter instruments [J].
Dahlback, A .
APPLIED OPTICS, 1996, 35 (33) :6514-6521
[3]   Global and zonal total ozone variations estimated from ground-based and satellite measurements: 1964-2000 [J].
Fioletov, VE ;
Bodeker, GE ;
Miller, AJ ;
McPeters, RD ;
Stolarski, R .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2002, 107 (D22)
[4]   An assessment of the world ground-based total ozone network performance from the comparison with satellite data [J].
Fioletov, VE ;
Kerr, JB ;
Hare, EW ;
Labow, GJ ;
McPeters, RD .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1999, 104 (D1) :1737-1747
[5]  
GAO W, 2001, APPL OPTICS, V40, P1511
[6]   AERONET - A federated instrument network and data archive for aerosol characterization [J].
Holben, BN ;
Eck, TF ;
Slutsker, I ;
Tanre, D ;
Buis, JP ;
Setzer, A ;
Vermote, E ;
Reagan, JA ;
Kaufman, YJ ;
Nakajima, T ;
Lavenu, F ;
Jankowiak, I ;
Smirnov, A .
REMOTE SENSING OF ENVIRONMENT, 1998, 66 (01) :1-16
[7]   Ozone column retrieval from solar UV irradiance measurements at ground level:: Sensitivity tests and uncertainty estimation -: art. no. D15302 [J].
Houët, M ;
Brogniez, C .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2004, 109 (D15) :D153021-11
[8]   Retrieval of ozone column from global irradiance measurements and comparison with TOMS data. A year of data in the Alps [J].
Masserot, D ;
Lenoble, J ;
Brogniez, C ;
Houet, M ;
Krotkov, N ;
McPeters, R .
GEOPHYSICAL RESEARCH LETTERS, 2002, 29 (09) :23-1
[9]  
McPeters R.D., 1998, NASA TECH PUBL, V1998
[10]  
SECKMEYER G, 2002, 6 EUR S STRAT OZ ENV