Inflammatory response to cardiopulmonary bypass using two different types of heparin-coated extracorporeal circuits

被引:16
作者
Baufreton, Christophe [1 ]
Moczar, Madeleine [2 ]
Intrator, Liliane [3 ]
Jansen, Piet G. M. [4 ]
te Velthuis, Henk
Le Besnerais, Paul [1 ]
Farcet, Jean Pierre [3 ]
Wildevuur, Charles R. H. [4 ]
Loisance, Daniel Y. [1 ]
机构
[1] Hop Henri Mondor, Dept Thorac & Cardiovasc Surg, F-94010 Creteil, France
[2] CNRS, URA 1431, Ctr Rech Chirurg, F-75700 Paris, France
[3] Hop Henri Mondor, Serv Immunol Biol, F-94010 Creteil, France
[4] Free Univ Amsterdam Hosp, Dept Cardiac Surg, Amsterdam, Netherlands
来源
PERFUSION-UK | 1998年 / 13卷 / 06期
关键词
D O I
10.1177/026765919801300605
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous reports have highlighted the disparity in biocompatibility of two differently engineered heparin coatings during the cardiopulmonary bypass (CPB) procedure. The aim of this prospective study was to evaluate the impact of the difference in haemocompatibility provided by either the Duraflo II equipment or the Carmeda equipment in the terminal inflammatory response observed after coronary artery surgery. Thirty patients were randomly allocated to two groups to be operated on using either Duraflo II equipment (group I) or Carmeda equipment (group 2) for extracorporeal circulation (ECC). Initial inflammatory response was assessed by terminal complement complex activation (SC5b-9). The late inflammatory response observed in the postoperative period was assessed by measuring cytokine production (tumour factor necrosis (TNF alpha), interleukin IL-6, interleukin IL-8) and circulating concentrations of adhesion molecules (ELAM-1, ICAM-1). The release of SC5b-9 after CPB and after protamine administration was lower in group 2 than in group 1 (p = 0.0002 and p = 0.006, respectively). A significant production of cytokines was detected in both groups with peak values observed within the time range of 4-6 h after the start of CPB. However, no difference was observed between the groups except for the IL-8 level in group 2, which was lower 2 h after the start of CPB (p = 0.01). Plasma levels of adhesion molecules were similar in both groups within the investigation period. Although the Carmeda equipment was more effective in reducing complement activation, the late inflammatory response was similar using either the Duraflo II or Carmeda equipment for extracorporeal circulation as reflected by the changes of cytokine and circulating adhesion molecule levels.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 30 条
[1]  
Ashraf S, 1997, ANN THORAC SURG, V63, P68
[2]   RETRACTED: CIRCULATING ADHESION MOLECULES IN CARDIAC OPERATIONS - INFLUENCE OF HIGH-DOSE APROTININ (Retracted article. See vol. 111, 2021) [J].
BOLDT, J ;
OSMER, C ;
SCHINDLER, E ;
LINKE, LC ;
STERTMANN, WA ;
HEMPELMANN, G .
ANNALS OF THORACIC SURGERY, 1995, 59 (01) :100-105
[3]  
BOONSTRA PW, 1985, J THORAC CARDIOV SUR, V89, P900
[4]  
BOROWIEC J, 1992, J THORAC CARDIOV SUR, V104, P642
[5]   ROLE OF CYTOKINES IN THE PATHOGENESIS OF CARDIOPULMONARY-INDUCED MULTISYSTEM ORGAN FAILURE [J].
CASEY, LC .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :S92-S96
[6]   Biocompatibility of three different membrane oxygenators: effects on complement, neutrophil and monocyte activation [J].
de Vroege, R. ;
Rutten, P. M. M. J. ;
Kalkman, C. ;
Out, T. A. ;
Jansen, P. G. M. ;
Eijsman, L. ;
de Mol, B. J. M. ;
Wildevuur, C. R. H. .
PERFUSION-UK, 1997, 12 (06) :369-375
[7]   ARTERIAL AND VENOUS CYTOKINE RESPONSE TO CARDIOPULMONARY BYPASS FOR LOW-RISK CABG AND RELATION TO HEMODYNAMICS [J].
DENG, MC ;
WIEDNER, M ;
ERREN, M ;
MOLLHOFF, T ;
ASSMANN, G ;
SCHELD, HH .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1995, 9 (01) :22-29
[8]   BLOOD-SURFACE INTERACTIONS DURING CARDIOPULMONARY BYPASS [J].
EDMUNDS, LH .
JOURNAL OF CARDIAC SURGERY, 1993, 8 (03) :404-410
[9]  
FRERING B, 1994, J THORAC CARDIOV SUR, V108, P636
[10]   HEPARIN-COATED CIRCUITS REDUCE THE INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS [J].
GU, YJ ;
VANOEVEREN, W ;
AKKERMAN, C ;
BOONSTRA, PW ;
HUYZEN, RJ ;
WILDEVUUR, CRH .
ANNALS OF THORACIC SURGERY, 1993, 55 (04) :917-922