Limits and potentials of office building climatisation with ambient air

被引:29
作者
Eicker, U [1 ]
Huber, M [1 ]
Seeberger, P [1 ]
Vorschulze, C [1 ]
机构
[1] Univ Appl Sci Stuttgart, D-70174 Stuttgart, Germany
关键词
passive cooling; Earth to air heat exchanger; summer building performance; passive building standard;
D O I
10.1016/j.enbuild.2005.09.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the first passive energy standard office buildings in Europe was extensively monitored over 3 years to analyse the summer performance of highly insulated, well sun-shaded and mechanically ventilated buildings. During typical German summer conditions with less than 160 hours ambient air temperatures above 25 degrees C, these buildings perform excellently during summer, even if the internal loads are rather high with 200-400 Wh m(-2) day(-1). If ambient air temperatures are significantly higher like in summer 2003 with more than 3 K higher average temperatures than usual, nearly 10% of all office hours are above 26 degrees C. Detailed measurements showed that the night discharging of heavy thermal masses such as the concrete ceiling was not always effective under free convection conditions. Room air temperature decreased by 2-3 K only although measured night air changes were always above 5 h(-1). The measured air change rates contained not only cool ambient air but also backflow of warmer air from the corridors, which could be shown by flow visualisation in the rooms and by simulation studies. Improvements to the night ventilation performance can be achieved, if early evening ventilation with high heat gains can be reduced and if fans support the air exchange in the cooler morning hours. Three year measurements and simulation of the earth heat exchanger showed that excellent performance is achieved with COP's between 35 and 50. Due to the limited fresh air volume flow in such buildings, the earth heat exchanger only removes a fraction of the loads, here about 18% of the total internal loads. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 581
页数:8
相关论文
共 10 条
[1]  
ALBERS KJ, 1991, 32 DTSCH KALT KLIM V
[2]  
Dibowski G., 2000, HLH, V51, P32
[3]  
HENNE A, 1999, TAB, V10, P55
[4]   Design, monitoring and evaluation of a low energy office building with passive cooling by night ventilation [J].
Pfafferott, J ;
Herkel, S ;
Wambsganss, M .
ENERGY AND BUILDINGS, 2004, 36 (05) :455-465
[5]   Design of passive cooling by night ventilation:: evaluation of a parametric model and building simulation with measurements [J].
Pfafferott, J ;
Herkel, S ;
Jäschke, M .
ENERGY AND BUILDINGS, 2003, 35 (11) :1129-1143
[6]   Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency [J].
Pfafferott, J .
ENERGY AND BUILDINGS, 2003, 35 (10) :971-983
[7]  
SCHUMACHER J, 2004, SIMULATION ENV INSEL
[8]   Thermal mass and night ventilation as passive cooling design strategy [J].
Shaviv, E ;
Yezioro, A ;
Capeluto, IG .
RENEWABLE ENERGY, 2001, 24 (3-4) :445-452
[9]   ANALYSIS OF THE ACCURACY AND SENSITIVITY OF 8 MODELS TO PREDICT THE PERFORMANCE OF EARTH-TO-AIR HEAT-EXCHANGERS [J].
TZAFERIS, A ;
LIPARAKIS, D ;
SANTAMOURIS, M ;
ARGIRIOU, A .
ENERGY AND BUILDINGS, 1992, 18 (01) :35-43
[10]  
ZIMMERMANN M, 2003, HDB PASSIVEN KU HLUN