Large scale real-time PCR validation on gene expression measurements from two commercial long-oligonucleotide microarrays

被引:213
作者
Wang, YL [1 ]
Barbacioru, C [1 ]
Hyland, F [1 ]
Xiao, WM [1 ]
Hunkapiller, KL [1 ]
Blake, J [1 ]
Chan, F [1 ]
Gonzalez, C [1 ]
Zhang, L [1 ]
Samaha, RR [1 ]
机构
[1] Appl Biosyst Inc, Div Mol Biol, Foster City, CA 94404 USA
关键词
D O I
10.1186/1471-2164-7-59
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: DNA microarrays are rapidly becoming a fundamental tool in discovery-based genomic and biomedical research. However, the reliability of the microarray results is being challenged due to the existence of different technologies and non-standard methods of data analysis and interpretation. In the absence of a "goldstandard"/"reference method" for the gene expression measurements, studies evaluating and comparing the performance of various microarray platforms have often yielded subjective and conflicting conclusions. To address this issue we have conducted a large scale TaqMan(R) Gene Expression Assay based real-time PCR experiment and used this data set as the reference to evaluate the performance of two representative commercial microarray platforms. Results: In this study, we analyzed the gene expression profiles of three human tissues: brain, lung, liver and one universal human reference sample (UHR) using two representative commercial long-oligonucleotide microarray platforms: ( 1) Applied Biosystems Human Genome Survey Microarrays ( based on single-color detection); ( 2) Agilent Whole Human Genome Oligo Microarrays ( based on two-color detection). 1,375 genes represented by both microarray platforms and spanning a wide dynamic range in gene expression levels, were selected for TaqMan(R) Gene Expression Assay based real-time PCR validation. For each platform, four technical replicates were performed on the same total RNA samples according to each manufacturer's standard protocols. For Agilent arrays, comparative hybridization was performed using incorporation of Cy5 for brain/lung/liver RNA and Cy3 for UHR RNA ( common reference). Using the TaqMan(R) Gene Expression Assay based realtime PCR data set as the reference set, the performance of the two microarray platforms was evaluated focusing on the following criteria: ( 1) Sensitivity and accuracy in detection of expression; ( 2) Fold change correlation with real-time PCR data in pair-wise tissues as well as in gene expression profiles determined across all tissues; ( 3) Sensitivity and accuracy in detection of differential expression. Conclusion: Our study provides one of the largest "reference" data set of gene expression measurements using TaqMan(R) Gene Expression Assay based real-time PCR technology. This data set allowed us to use an alternative gene expression technology to evaluate the performance of different microarray platforms. We conclude that microarrays are indeed invaluable discovery tools with acceptable reliability for genome-wide gene expression screening, though validation of putative changes in gene expression remains advisable. Our study also characterizes the limitations of microarrays; understanding these limitations will enable researchers to more effectively evaluate microarray results in a more cautious and appropriate manner.
引用
收藏
页数:16
相关论文
共 27 条
[1]   Basic principles of real-time quantitative PCR [J].
Arya, M ;
Shergill, IS ;
Williamson, M ;
Gommersall, L ;
Arya, N ;
Patel, HRH .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2005, 5 (02) :209-219
[2]   A comparison of normalization methods for high density oligonucleotide array data based on variance and bias [J].
Bolstad, BM ;
Irizarry, RA ;
Åstrand, M ;
Speed, TP .
BIOINFORMATICS, 2003, 19 (02) :185-193
[3]  
Chambers JM., 1992, Statistical models
[4]   Normalization of gene expression measurements in tumor tissues: comparison of 13 endogenous control genes [J].
de Kok, JB ;
Roelofs, RW ;
Giesendorf, BA ;
Pennings, JL ;
Waas, ET ;
Feuth, T ;
Swinkels, DW ;
Span, PN .
LABORATORY INVESTIGATION, 2005, 85 (01) :154-159
[5]  
FAWCETT T, 2004, HPL20034
[6]   Microarray data - the USFDA, industry and academia [J].
Hackett, JL ;
Lesko, LJ .
NATURE BIOTECHNOLOGY, 2003, 21 (07) :742-743
[7]  
Huber Wolfgang, 2002, Bioinformatics, V18 Suppl 1, pS96
[8]   Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer [J].
Hughes, TR ;
Mao, M ;
Jones, AR ;
Burchard, J ;
Marton, MJ ;
Shannon, KW ;
Lefkowitz, SM ;
Ziman, M ;
Schelter, JM ;
Meyer, MR ;
Kobayashi, S ;
Davis, C ;
Dai, HY ;
He, YDD ;
Stephaniants, SB ;
Cavet, G ;
Walker, WL ;
West, A ;
Coffey, E ;
Shoemaker, DD ;
Stoughton, R ;
Blanchard, AP ;
Friend, SH ;
Linsley, PS .
NATURE BIOTECHNOLOGY, 2001, 19 (04) :342-347
[9]   Multiple-laboratory comparison of microarray platforms [J].
Irizarry, RA ;
Warren, D ;
Spencer, F ;
Kim, IF ;
Biswal, S ;
Frank, BC ;
Gabrielson, E ;
Garcia, JGN ;
Geoghegan, J ;
Germino, G ;
Griffin, C ;
Hilmer, SC ;
Hoffman, E ;
Jedlicka, AE ;
Kawasaki, E ;
Martínez-Murillo, F ;
Morsberger, L ;
Lee, H ;
Petersen, D ;
Quackenbush, J ;
Scott, A ;
Wilson, M ;
Yang, YQ ;
Ye, SQ ;
Yu, W .
NATURE METHODS, 2005, 2 (05) :345-349
[10]   Independence and reproducibility across microarray platforms [J].
Larkin, JE ;
Frank, BC ;
Gavras, H ;
Sultana, R ;
Quackenbush, J .
NATURE METHODS, 2005, 2 (05) :337-343