Increased myocardial echo density in left ventricular pressure and volume overload in human aortic valvular disease: An ultrasonic tissue characterization study
被引:13
作者:
DiBello, V
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
DiBello, V
Talarico, L
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Talarico, L
Picano, E
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Picano, E
Giorgi, D
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Giorgi, D
Bertini, A
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Bertini, A
Paterni, M
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Paterni, M
Giusti, C
论文数: 0引用数: 0
h-index: 0
机构:II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Giusti, C
机构:
[1] II Clinical Medical Institute, University of Pisa, Institute of Clinical Physiology, Pisa
Quantitatively assessed ultrasonic backscatter is an index of ultrasonic tissue characterization directly related to morphometrically evaluated collagen content in human beings. Our objective was to assess myocardial reflectivity pattern in patients with severe left ventricular hypertrophy caused by either aortic stenosis (AS) or aortic regurgitation (AR). Ten patients with AS, 10 patients with AR, and 10 closely age- and gender-matched healthy controls were studied by two-dimensional Doppler echocardiography. By using an echocardiographic prototype, we performed a radiofrequency analysis to obtain quantitative operator-independent measurements of the integrated backscatter signal of the ventricular septum and the posterior wall (integrated backscatter index: IBI, expressed in percentage). All patients with stenosis or aortic insufficiency showed a normal regional and global resting systolic function (fractional shortening: AS = 36.0 +/- 6.6 versus AR = 40.3 +/- 6.2 versus control = 40.2 +/- 8.7; p = not significant [NS]). Left ventricular mass index (Devereux's formula) was markedly increased in patients with stenosis or aortic insufficiency (AS = 199.3 +/- 18 versus AR = 208.8 +/- 60 versus control = 97.3 +/- 11 g/m(2); p < 0.0001). Myocardial echo density was increased in patients with stenosis or aortic insufficiency in comparison with controls, both in the septum (IBI%: AR = 40.7 +/- 7.9 versus AS = 33.4 +/- 4.2 versus control = 23.0 +/- 6.2; p < 0.0001) and in the posterior wall (IBI%: AR = 27.1 +/- 4.3 versus AS = 23.0 +/- 2.6 versus control = 15.0 +/- 4.2; p < 0.0001). No significant correlations were found between septal and posterior wall IBI and their thickness. Abnormally increased myocardial echo density-possibly related to disproportionate collagen deposition-can be detected in patients with pressure or volume overload caused by aortic valve disease and without overt systolic dysfunction.