A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality

被引:37
作者
Hoerth, Rebecca M. [1 ,2 ]
Katunar, Maria R. [3 ]
Gomez Sanchez, Andrea [3 ]
Orellano, Juan C. [4 ]
Cere, Silvia M. [3 ]
Wagermaier, Wolfgang [1 ]
Ballarre, Josefina [3 ]
机构
[1] Max Planck Inst Colloids & Interfaces, Dept Biomat, D-14424 Potsdam, Germany
[2] Charite Campus Virchow Klinikum, Berlin Brandenburg Sch Regenerat Therapies BSRT, D-13353 Berlin, Germany
[3] Univ Nacl Mar del Plata, INTEMA, CONICET, Mar Del Plata, Buenos Aires, Argentina
[4] Hosp Interzonal Gen Agudos Oscar Alende, Mar Del Plata, Buenos Aires, Argentina
关键词
STAINLESS-STEEL IMPLANTS; CORROSION-RESISTANCE; SURFACE MODIFICATION; ANODIC-OXIDATION; IN-VITRO; COATINGS; BIOMATERIALS; FLUORESCENCE; PARTICLES; ACID;
D O I
10.1007/s10856-013-5074-3
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.
引用
收藏
页码:411 / 422
页数:12
相关论文
共 37 条
[1]
Morphologic and nanomechanical characterization of bone tissue growth around bioactive sol-gel coatings containing wollastonite particles applied on stainless steel implants [J].
Ballarre, Josefina ;
Seltzer, Rocio ;
Mendoza, Emigdio ;
Carlos Orellano, Juan ;
Mai, Yiu-Wing ;
Garcia, Claudia ;
Cere, Silvia M. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (03) :545-552
[2]
Improving the osteointegration and bone-implant interface by incorporation of bioactive particles in sol-gel coatings of stainless steel implants [J].
Ballarre, Josefina ;
Manjubala, Inderchand ;
Schreiner, Wido H. ;
Carlos Orellano, Juan ;
Fratzl, Peter ;
Cere, Silvia .
ACTA BIOMATERIALIA, 2010, 6 (04) :1601-1609
[3]
Cabrini R L, 1993, Implant Dent, V2, P264
[4]
Organic-inorganic hybrid coatings for corrosion protection [J].
Chou, TP ;
Chandrasekaran, C ;
Limmer, SJ ;
Seraji, S ;
Wu, Y ;
Forbess, MJ ;
Nguyen, C ;
Cao, GZ .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2001, 290 (2-3) :153-162
[5]
Porous scaffold architecture guides tissue formation [J].
Cipitria, Amaia ;
Lange, Claudia ;
Schell, Hanna ;
Wagermaier, Wolfgang ;
Reichert, Johannes C. ;
Hutmacher, Dietmar W. ;
Fratzl, Peter ;
Duda, Georg N. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (06) :1275-1288
[6]
Cipriano Cara A, 2008, Am J Orthop (Belle Mead NJ), V37, pE18
[7]
Effects of tissue age on bone tissue material composition and nanomechanical properties in the rat cortex [J].
Donnelly, Eve ;
Boskey, Adele L. ;
Baker, Shefford P. ;
van der Meulen, Marjolein C. H. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (03) :1048-1056
[8]
Fathi MH, 2003, DENT RES J, V1, P36
[9]
Cortical bone composition and orientation as a function of animal and tissue age in mice by Raman spectroscopy [J].
Gamsjaeger, Sonja ;
Masic, A. ;
Roschger, P. ;
Kazanci, M. ;
Dunlop, J. W. C. ;
Klaushofer, K. ;
Paschalis, E. P. ;
Fratzl, P. .
BONE, 2010, 47 (02) :392-399
[10]
Surface modification of titanium by anodic oxidation in phosphoric acid at low potentials. Part 1. Structure, electronic properties and thickness of the anodic films [J].
Gomez Sanchez, A. ;
Schreiner, W. ;
Duffo, G. ;
Cere, S. .
SURFACE AND INTERFACE ANALYSIS, 2013, 45 (06) :1037-1046