Routine analysis of off-flavor compounds in water at sub-part-per-trillion level by large-volume injection GC/MS with programmable temperature vaporizing inlet

被引:55
作者
Zhang, LF [1 ]
Hu, RK [1 ]
Yang, ZG [1 ]
机构
[1] Singapore Utilities Int, Ctr Adv Water Technol, Singapore 637723, Singapore
关键词
water; off-flavor; large-volume injection (LVI); programmable temperature vaporizing (PTV); GC-MS;
D O I
10.1016/j.watres.2005.11.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Earthy- musty off-flavor problem in water samples are due to organic compounds present at the sub-part-per-trillion level. Most of the developments in the analysis of tastes and odorous compounds focus on the extraction pre-concentration technique, with detection at picogram per liter level of the earthy-musty off-flavor compounds difficult to be achieved. The objective of this study is to develop a new method involving the large-volume injection (LVI) GC/MS via programmable temperature vaporizing (PTV) inlet and continuous liquid-liquid extraction, to attain analytical sensitivity equal to or better than olfactory sensitivity. Six "earthy-musty" organic compounds, 2-methylisoborneol (MIB), geosmin, 2,4,6-trichloroanisole, 2,3,6-trichloroanisole, 2,3,4-trichloroanisole and 2,4,6-tribromoanisole, were used as probes for this study. it was found that LVI via PTV could greatly improve system sensitivity towards off-flavor compound detection. Variable instrument conditions and sample preparation conditions were studied in detail. This reliable and efficient method has been optimized and validated. The method detection limit were found to be from 35 to 70 pg/L for haloanisoles, 50 pg/L for geosmin and 0.34 ng/L for MIB, with relative standard deviation of calibration curve ranging from 4.7% to 15.1% and recovery ranging from 58% to 96%. This method has been successfully applied to test off-flavor compounds in different types of water samples with satisfactory results. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:699 / 709
页数:11
相关论文
共 28 条
[1]
[Anonymous], 1992, SW846 US EPA
[2]
ANSELME C, 1985, AWWA WQTC HOUST TX
[3]
Pesticide residue analysis in waters by solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry [J].
Arrebola, FJ ;
Aguado, SC ;
Sánchez-Morito, N ;
Frenich, AG ;
Vidal, JLM .
ANALYTICAL LETTERS, 2004, 37 (01) :99-117
[4]
Determination of trace levels of taste and odor compounds in water by microextraction and gas chromatography ion trap detection mass spectrometry [J].
Bao, ML ;
Barbieri, K ;
Burrini, D ;
Griffini, O ;
Pantani, F .
WATER RESEARCH, 1997, 31 (07) :1719-1727
[5]
BENANOU D, 2003, AGILENT PUBLICATION
[6]
BOA ML, 1997, WATER RES, V31, P1719
[7]
Brück M, 1999, ASTRON GEOPHYS, V40, P6
[8]
Determination of odorous mixed chloro-bromoanisoles in water by solid-phase micro-extraction and gas chromatography-mass detection [J].
Díaz, A ;
Ventura, F ;
Galceran, T .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (01) :97-106
[9]
Programmed temperature vaporiser-based injection in capillary gas chromatography [J].
Engewald, W ;
Teske, J ;
Efer, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :259-278
[10]
ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155