Histomorphological reaction of bone to different concentrations of phagocytosable particles of high-density polyethylene and Ti-6Al-4V alloy in vivo

被引:29
作者
Goodman, SB
Davidson, JA
Song, Y
Martial, N
Fornasier, VL
机构
[1] SMITH & NEPHEW RICHARDS INC,ORTHOPAED RES DEPT,MEMPHIS,TN 38116
[2] WELLESLEY HOSP,DEPT PATHOL,TORONTO,ON,CANADA
关键词
particles; phagocytosis; polyethylene; Ti-6Al-4V alloy; animal model;
D O I
10.1016/0142-9612(96)00013-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear debris has been implicated in the pathogenesis of loosening and osteolysis of total joint replacements by stimulating a foreign body and chronic inflammatory reaction capable of bone resorption. Whether increasing concentrations of wear particles have an adverse biological effect on bone has not been elucidated. We performed a histomorphological and semi-quantitative morphometric analysis of the reaction of bone to different concentrations of phagocytosable particles of high-density polyethylene (HDPE) and titanium 6-aluminium 4-vanadium alloy (Ti-6Al-4V) implanted in the rabbit tibia. The Ti-6Al-4V particles had a diameter of 4.0+/-4.4 mu m (mean+/-SD); the HDPE particles averaged 4.7+/-2.1 mu m. Suspensions of 10(6)-10(9) particles per mi were mixed in saline, sterilized, and introduced through a drill hole into the proximal tibia of 30 mature female rabbits. Controls included drilled, but non-implantable limbs. The animals were killed at 16 weeks and histological sections were made of the implant area. Histomorphological assessment was carried out using an interactive image analysis system. The parameters assessed included the presence of histiocytes, foreign body giant cells and inflammatory cells, the location and number of particles, the presence of haematopoeitic elements, fat or necrosis of the marrow, whether healing of the cortical window had taken place, and whether there was evidence of formation or resorption of bone by the periosteum, cortex and marrow. A semi-quantitative rating system was employed. Phagocytosable particles of Ti-6Al-4V and HDPE, in concentrations of 10(6)-10(9) particles per ml, evoked a histiocytic reaction without extensive fibrosis, necrosis or granuloma formation. This reaction occurred without disturbing the normal repair processes of bone formation and resorption to the surgical insult. A clear dose-response effect on the histological parameters assessed in this study was not noted. Using the present model, by 16 weeks, a similar 'one time' particle load could be accommodated. The ongoing generation of particulate debris over a more extended period of time might be necessary before the remodelling processes of bone would be disturbed. (C) 1996 Elsevier Science Limited.
引用
收藏
页码:1943 / 1947
页数:5
相关论文
共 25 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]  
[Anonymous], 1992, SOCIOLOGICA, V7
[3]  
BRIEN WW, 1990, T 36 ANN M ORTH RES, P27
[4]  
BULLOUGH PG, 1973, HIP, P80
[5]  
DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P213
[6]   THE EFFECTS OF BONE-CEMENT POWDER ON HUMAN ADHERENT MONOCYTES MACROPHAGES IN-VITRO [J].
DAVIS, RG ;
GOODMAN, SB ;
SMITH, RL ;
LERMAN, JA ;
WILLIAMS, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (08) :1039-1046
[7]  
GLANT TT, 1993, J BONE MINER RES, V8, P1071
[8]   THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS [J].
GOLDRING, SR ;
SCHILLER, AL ;
ROELKE, M ;
ROURKE, CM ;
ONEILL, DA ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :575-584
[9]   EFFECTS OF PARTICULATE HIGH-DENSITY POLYETHYLENE AND TITANIUM-ALLOY ON TISSUE INGROWTH INTO BONE HARVEST CHAMBER IN RABBITS [J].
GOODMAN, S ;
ASPENBERG, P ;
SONG, Y ;
DOSHI, A ;
REGULA, D ;
LIDGREN, L .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :27-33
[10]   THE HISTOLOGICAL EFFECTS OF THE IMPLANTATION OF DIFFERENT SIZES OF POLYETHYLENE PARTICLES IN THE RABBIT TIBIA [J].
GOODMAN, SB ;
FORNASIER, VL ;
LEE, J ;
KEI, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (04) :517-524