Extracting metabolite ions out of a matrix background by combined mass defect, neutral loss and isotope filtration

被引:42
作者
Cuyckens, Filip [1 ]
Hurkmans, Rob [1 ]
Castro-Perez, Jose M. [2 ]
Leclercq, Laurent [1 ]
Mortishire-Smith, Russell J. [3 ]
机构
[1] Johnson & Johnson Pharmaceut R&D, Global Preclin Dev, B-2340 Beerse, Belgium
[2] Waters Corp, MS Technol Ctr, Manchester M22 5PP, Lancs, England
[3] Johnson & Johnson Pharmaceut R&D, ADME TOX, B-2340 Beerse, Belgium
关键词
BIOLOGICAL MATRICES; SPECTROMETRY; DRUG;
D O I
10.1002/rcm.3881
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass defect, neutral loss and isotope filtration techniques were applied to electrospray ionization mass spectrometry (EST-MS) data obtained for in vivo and in vitro samples of drug metabolism studies. A combination of these post-acquisition processing techniques was shown to be more powerful than the use of one of these tools alone for the detection in complex matrices of metabolites of candidate drugs with a characteristic isotope pattern (e.g. containing bromine, chlorine, or a high proportion of radiolabeled drug (C-12/C-14)) or characteristic neutral losses. In combination with 'all-in-one' data acquisition this methodology is able to perform software-driven constant neutral loss scanning for an unlimited number of mass differences at any time after analysis. Highly selective MS chromatograms were obtained with excellent correlation with their corresponding radiochromatograms. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 10 条
[1]   MSE with mass defect filtering for in vitro and in vivo metabolite identification [J].
Bateman, Kevin P. ;
Castro-Perez, Jose ;
Wrona, Mark ;
Shockcor, John P. ;
Yu, Kate ;
Oballa, Renata ;
Nicoll-Griffith, Deborah A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (09) :1485-1496
[2]   Use of the bromine isotope ratio in HPLC-ICP-MS and HPLC-ESI-MS analysis of a new drug in development [J].
Cuyckens, Filip ;
Balcaen, Lieve I. L. ;
De Wolf, Kenny ;
De Samber, Bjorn ;
Van Looveren, Cis ;
Hurkmans, Rob ;
Vanhaecke, Frank .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) :1717-1729
[3]   A generic method to detect electrophilic intermediates using isotopic pattern triggered data-dependent high-resolution accurate mass spectrometry [J].
Lim, Heng-Keang ;
Chen, Jie ;
Cook, Kevin ;
Sensenhauser, Carlo ;
Silva, Jose ;
Evans, David C. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (08) :1295-1311
[4]   Accelerated throughput metabolic route screening in early drug discovery using high-resolution liquid chromatography/quadrupole time-of-flight mass spectrometry and automated data analysis [J].
Mortishire-Smith, RJ ;
O'Connor, D ;
Castro-Perez, JM ;
Kirby, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) :2659-2670
[5]   An integrated method for metabolite detection and identification using a linear ion trap/Orbitrap mass spectrometer and multiple data processing techniques: application to indinavir metabolite detection [J].
Ruan, Qian ;
Peterman, Scott ;
Szewc, Mark A. ;
Ma, Li ;
Cui, Dan ;
Humphreys, W. Griffith ;
Zhu, Mingshe .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (02) :251-261
[6]   'All-in-One' analysis for metabolite identification using liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry with collision energy switching [J].
Wrona, M ;
Mauriala, T ;
Bateman, KP ;
Mortishire-Smith, RJ ;
O'Connor, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) :2597-2602
[7]   Mass defect profiles of biological matrices and the general applicability of mass defect filtering for metabolite detection [J].
Zhang, Haiying ;
Zhu, Mingshe ;
Ray, Kenneth L. ;
Ma, Li ;
Zhang, Donglu .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (13) :2082-2088
[8]   A software filter to remove interference ions from drug metabolites in accurate mass liquid chromatography/mass spectrometric analyses [J].
Zhang, HY ;
Zhang, DL ;
Ray, K .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (10) :1110-1112
[9]   Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass Spectrometry and mass defect filtering [J].
Zhu, Mingshe ;
Ma, Li ;
Zhang, Haiying ;
Humphreys, W. Griffith .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8333-8341
[10]   Detection and characterization of metabolites in biological matrices using mass defect filtering of liquid chromatography/high resolution mass spectrometry data [J].
Zhu, Mingshe ;
Ma, Li ;
Zhang, Donglu ;
Ray, Kenneth ;
Zhao, Weiping ;
Humphreys, W. Griffith ;
Skiles, Gary ;
Sanders, Mark ;
Zhang, Haiying .
DRUG METABOLISM AND DISPOSITION, 2006, 34 (10) :1722-1733