Accuracy of motor axon regeneration across autograft, single-lumen, and multichannel poly(lactic-co-glycolic acid) nerve tubes

被引:86
作者
de Ruiter, Godard C. [2 ,3 ]
Spinner, Robert J. [3 ]
Malessy, Martijn J. A. [5 ]
Moore, Michael J. [4 ]
Sorenson, Eric J. [1 ]
Currier, Bradford L. [6 ]
Yaszemski, Michael J. [4 ,6 ]
Windebank, Anthony J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[2] Mayo Clin, Cellular Neurobiol Lab, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Neurol Surg, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[5] Leiden Univ, Med Ctr, Dept Neurosurg, Leiden, Netherlands
[6] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
axon targeting; double labeling; misdirection; peripheral nerve regeneration; rat sciatic nerve model; retrograde tracing;
D O I
10.1227/01.NEU.0000335081.47352.78
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The accuracy of motor axon regeneration becomes an important issue in the development of a nerve tube for motor nerve repair. Dispersion of regeneration across the nerve tube may lead to misdirection and polyinnervation. In this study, we present a series of methods to investigate the accuracy of regeneration, which we used to compare regeneration across autografts and single-lumen poly(lactic-co-glycolic acid) (PLGA) nerve tubes. We also present the concept of the multichannel nerve tube that may limit dispersion by separately guiding groups of regenerating axons. METHODS: The simultaneous tracing of the tibial and peroneal nerves with fast blue and diamidino yellow was performed 8 weeks after the repair of a 1-cm nerve gap in the rat sciatic nerve to determine the percentage of double-projecting motoneurons. Sequential tracing of the peroneal nerve with diamidino yellow 1 week before repair and fast blue 8 weeks after repair was performed to determine the percentage of correctly directed peroneal motoneurons. RESULTS: In the cases in which there was successful regeneration across single-lumen nerve tubes, more motoneurons had double projections to both the tibial and peroneal nerve branches after single-lumen nerve tube repair (21.4%) than after autograft repair (5.9%). After multichannel nerve tube repair, this percentage was slightly reduced (16.9%), although not significantly. The direction of regeneration was nonspecific after all types of repair. CONCLUSION: Retrograde tracing techniques provide new insights into the process of regeneration across nerve tubes. The methods and data presented in this study can be used as a basis for the development of a nerve tube for motor nerve repair.
引用
收藏
页码:144 / 153
页数:10
相关论文
共 43 条
[1]   ESTIMATION OF NUCLEAR POPULATION FROM MICROTOME SECTIONS [J].
ABERCROMBIE, M .
ANATOMICAL RECORD, 1946, 94 (02) :239-247
[2]   Multi-channeled biodegradable polymer/CultiSpher composite nerve guides [J].
Bender, MD ;
Bennett, JM ;
Waddell, RL ;
Doctor, JS ;
Marra, KG .
BIOMATERIALS, 2004, 25 (7-8) :1269-1278
[3]  
BodineFowler SC, 1997, MUSCLE NERVE, V20, P29, DOI 10.1002/(SICI)1097-4598(199701)20:1<29::AID-MUS4>3.0.CO
[4]  
2-J
[5]   SOME COMMENTS ON HISTOCHEMICAL CHARACTERIZATION OF MUSCLE ADENOSINE TRIPHOSPHATASE [J].
BROOKE, MH ;
KAISER, KK .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1969, 17 (06) :431-&
[6]   DISPERSION OF REGENERATING AXONS ACROSS ENCLOSED NEURAL GAPS [J].
BRUSHART, TM ;
MATHUR, V ;
SOOD, R ;
KOSCHORKE, GM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (04) :557-564
[7]   Methods for in vitro characterization of multichannel nerve tubes [J].
de Ruiter, Godard C. ;
Onyeneho, Irene A. ;
Liang, Ellen T. ;
Moore, Michael J. ;
Knight, Andrew M. ;
Malessy, Martijn J. A. ;
Spinner, Robert J. ;
Lu, Lichun ;
Currier, Bradford L. ;
Yaszemski, Michael J. ;
Windebank, Anthony J. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (03) :643-651
[8]   Misdirection of regenerating motor axons after nerve injury and repair in the rat sciatic nerve model [J].
de Ruiter, Godard C. W. ;
Malessy, Martijn J. A. ;
Alaid, Awad O. ;
Spinner, Robert J. ;
Engelstad, JaNean K. ;
Sorenson, E. J. ;
Kaufman, K. R. ;
Dyck, Peter J. ;
Windebank, Anthony J. .
EXPERIMENTAL NEUROLOGY, 2008, 211 (02) :339-350
[9]   Reconstruction of the spinal accessory nerve with autograft or neurotube? Two case reports [J].
Ducic, I ;
Maloney, CT ;
Dellon, AL .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2005, 21 (01) :29-33
[10]  
DYCK PJ, 2005, PATHOLOGIC ALTERATIO, V1