RETRACTED: Balanced hydroxyethylstarch preparations: are they all the same? In-vitro thrombelastometry and whole blood aggregometry (Retracted Article)

被引:6
作者
Boldt, Joachim [1 ]
Mengistu, Andinet [1 ]
机构
[1] Klinikum Stadt Ludwigshafen, Dept Anesthesiol & Intens Care Med, D-67063 Ludwigshafen, Germany
关键词
balanced hydroxyethylstarch; gelatin; haemodilution; platelet function; thrombelastometry; whole blood aggregomery; LACTATED RINGERS SOLUTION; SEE VOL. 25; PLATELET-FUNCTION; STARCH SOLUTIONS; MAJOR SURGERY; COAGULATION; HETASTARCH; HEMODILUTION; SUBSTITUTION; HEMOSTASIS;
D O I
10.1097/EJA.0b013e32832f5a90
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective Haemostasis appears to be less altered with balanced than with unbalanced hydroxyethylstarch (HES) preparations. In a blinded in-vitro coagulation study, the effects of two HESs dissolved in different balanced solutions were measured. Methods Blood from 12 healthy young male volunteers was diluted by 10, 30 and 50% by using either a balanced 6% HES 130/0.42 or a balanced 6% HES 130/0.4. Composition of the solvent of the two HES preparations differed. An unbalanced gelatin solution was used as a control. Rotation thrombelastometry was used to assess changes in coagulation, and whole blood aggregometry using three different inductors was used to assess the effects of dilution on platelet function. Results Dilutions of 10 and 30% showed no significant changes in thrombelastometry data and platelet aggregation in all three groups. Fifty per cent haemodilution was associated with significantly more pronounced deterioration in clotting time, clot formation time and clot firmness, with the balanced HES 130/0.42 containing calcium than with the balanced HES without calcium. Platelet function was also more impaired by HES not containing calcium than by HES containing calcium. Extreme dilution with gelatin showed similar results to those of balanced HES 130/0.4. Conclusion Our in-vitro studies showed that extreme haemodilution with HES 130/0.42 dissolved in a balanced solution containing calcium was associated with less negative effects on thrombelastometry and platelet aggregation than HES 130/0.4 prepared in a balanced solution without calcium. Gelatin prepared in a nonbalanced solution showed similar effects on coagulation to balanced HES without calcium. Eur J Anaesthesiol 26:1020-1025 (C) 2009 European Society of Anaesthesiology.
引用
收藏
页码:1020 / 1025
页数:6
相关论文
共 28 条
[1]   The effect of hydroxyethyl starch on platelet aggregation in vitro [J].
Blaicher, AM ;
Reiter, WJ ;
Blaicher, W ;
Kettner, SC ;
Felfernig, M ;
Grabner, CM ;
Zimpfer, M .
ANESTHESIA AND ANALGESIA, 1998, 86 (06) :1318-1321
[2]   Effects of different plasma substitutes on blood coagulation: A comparative review [J].
de Jonge, E ;
Levi, M .
CRITICAL CARE MEDICINE, 2001, 29 (06) :1261-1267
[3]   The effects of high molecular weight hydroxyethyl starch solutions on platelets [J].
Deusch, E ;
Thaler, U ;
Kozek-Langenecker, SA .
ANESTHESIA AND ANALGESIA, 2004, 99 (03) :665-668
[4]   The effects of hydroxyethyl starches of varying molecular weights on platelet function [J].
Franz, A ;
Bräunlich, P ;
Gamsjäger, T ;
Felfernig, M ;
Gustorff, B ;
Kozek-Langenecker, SA .
ANESTHESIA AND ANALGESIA, 2001, 92 (06) :1402-1407
[5]   The effect of the combined administration of colloids and lactated Ringer's solution on the coagulation system:: An in vitro study using Thrombelastograph® coagulation analysis (ROTEG®) [J].
Fries, D ;
Innerhofer, P ;
Klingler, A ;
Berresheim, U ;
Mittermayr, M ;
Calatzis, A ;
Schobersberger, W .
ANESTHESIA AND ANALGESIA, 2002, 94 (05) :1280-1287
[6]   Hextend®, a physiologically balanced plasma expander for large volume use in major surgery:: A randomized phase III clinical trial [J].
Gan, TJ ;
Bennett-Guerrero, E ;
Phillips-Bute, B ;
Wakeling, H ;
Moskowitz, DM ;
Olufolabi, Y ;
Konstadt, SN ;
Bradford, C ;
Glass, PSA ;
Machin, SJ ;
Mythen, MG .
ANESTHESIA AND ANALGESIA, 1999, 88 (05) :992-998
[7]   Coagulation monitoring: Current techniques and clinical use of viscoelastic point-of-care coagulation devices [J].
Ganter, Michael T. ;
Hofer, Christoph K. .
ANESTHESIA AND ANALGESIA, 2008, 106 (05) :1366-1375
[8]   Preparation for regional anaesthesia induces changes in thrombelastography [J].
Gorton, H ;
Lyons, G ;
Manraj, P .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (03) :403-404
[9]   RETRACTED: Influence of a new hydroxyethylstarch preparation (HES 130/0.4) on coagulation in cardiac surgical patients (Retracted article. See vol. 25, pg. 755, 2011) [J].
Haisch, G ;
Boldt, J ;
Krebs, C ;
Suttner, S ;
Lehmann, A ;
Isgro, F .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (03) :316-321
[10]  
Halmaja Hillman K, 1997, BAILLIERE CLIN ANAES, V11, P1