Acute testicular torsion: Comparison of unenhanced and contrast-enhanced power Doppler US, color Doppler US, and radionuclide imaging

被引:45
作者
Coley, BD
Frush, DP
Babcock, DS
OHara, SM
Lewis, AG
Gelfand, MJ
Bove, KE
Sheldon, CA
机构
[1] CHILDRENS HOSP,DEPT UROL,CINCINNATI,OH 45229
[2] CHILDRENS HOSP,DEPT PATHOL,CINCINNATI,OH 45229
[3] DUKE UNIV,MED CTR,DEPT RADIOL,DURHAM,NC 27710
关键词
testis; radionuclide studies; torsion; US;
D O I
10.1148/radiology.199.2.8668791
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the usefulness of conventional color Doppler ultrasound (US), unenhanced and contrast material-enhanced power Doppler US, and radionuclide imaging in a model of acute testicular torsion. MATERIALS AND METHODS: Twenty rabbits underwent unilateral 360 degrees testis torsion and contralateral orchiopexy. Gray-scale, color Doppler, and unenhanced and contrast-enhanced power Doppler US were performed 4-6 hours later. The side of torsion was determined, and intratestis flow tvas graded. Within 2 hours of US, technetium-99m pertechnetate was intravenously administered, the rabbits were killed, and the testes excised for radionuclide imaging. RESULTS: Intratestis perfusion was detected in 85% of torsed testes at US and radionuclide imaging. The side of torsion was correctly diagnosed in 25% of cases with radionuclide imaging and in 60% of cases with US. Power Doppler US demonstrated significantly greater intratestis flow in pexed than in torsed testes. Although the numbers of correct diagnosis with the three US modalities were similar, flow grades within torsed and normal testes were significantly different. CONCLUSION Perfusion to torsed and normal testes was demonstrated equally well with color Doppler US, power Doppler US, and radionuclide imaging. Doppler US better depicted differences in intratesticular flow between torsed and normal testes.
引用
收藏
页码:441 / 446
页数:6
相关论文
共 20 条
[1]   THE NORMAL AND ABNORMAL SCROTUM IN CHILDREN - EVALUATION WITH COLOR DOPPLER SONOGRAPHY [J].
ATKINSON, GO ;
PATRICK, LE ;
BALL, TI ;
STEPHENSON, CA ;
BROECKER, BH ;
WOODARD, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) :613-617
[2]   SUSPECTED TESTICULAR TORSION AND ISCHEMIA - EVALUATION WITH COLOR DOPPLER SONOGRAPHY [J].
BURKS, DD ;
MARKEY, BJ ;
BURKHARD, TK ;
BALSARA, ZN ;
HALUSZKA, MM ;
CANNING, DA .
RADIOLOGY, 1990, 175 (03) :815-821
[3]   IMMEDIATE EXPLORATION OF THE UNILATERAL ACUTE SCROTUM IN YOUNG MALE-SUBJECTS [J].
CASS, AS ;
CASS, BP ;
VEERARAGHAVAN, K .
JOURNAL OF UROLOGY, 1980, 124 (06) :829-832
[4]   COLOR DOPPLER ULTRASONOGRAPHY IN THE EVALUATION OF THE ACUTE SCROTUM [J].
DEWIRE, DM ;
BEGUN, FP ;
LAWSON, RK ;
FITZGERALD, S ;
FOLEY, WD .
JOURNAL OF UROLOGY, 1992, 147 (01) :89-91
[5]  
FELD R, 1992, RADIOL CLIN N AM, V30, P1033
[6]  
FITZGERALD SW, 1992, J ULTRAS MED, V11, P543
[7]   COMPARISON OF COLOR DOPPLER SONOGRAPHY AND RADIONUCLIDE IMAGING IN DIFFERENT DEGREES OF TORSION IN RABBIT TESTES [J].
FRUSH, DP ;
BABCOCK, DS ;
LEWIS, AG ;
PALTIEL, HJ ;
RUPICH, R ;
BOVE, KE ;
SHELDON, CA .
ACADEMIC RADIOLOGY, 1995, 2 (11) :945-951
[8]  
Heyman S., 1994, PEDIAT NUCL IMAGING, P195
[9]   COLOR DOPPLER SONOGRAPHY OF THE NORMAL PEDIATRIC TESTIS [J].
INGRAM, S ;
HOLLMAN, AS .
CLINICAL RADIOLOGY, 1994, 49 (04) :266-267
[10]   DO ALL CHILDREN WITH AN ACUTE SCROTUM REQUIRE EXPLORATION [J].
KASS, EJ ;
STONE, KT ;
CACCIARELLI, AA ;
MITCHELL, B .
JOURNAL OF UROLOGY, 1993, 150 (02) :667-669