Clinical implementation of a Monte Carlo treatment planning system

被引:231
作者
Ma, CM [1 ]
Mok, E [1 ]
Kapur, A [1 ]
Pawlicki, T [1 ]
Findley, D [1 ]
Brain, S [1 ]
Forster, K [1 ]
Boyer, AL [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
radiotherapy treatment planning; dose calculation; Monte Carlo simulation; Monte Carlo treatment planning; EGS4 Monte Carlo;
D O I
10.1118/1.598729
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used to reconstruct the phase-space data for both electron and photon beams, which retained the accuracy of the Monte Carlo beam data. The multiple-source model reduced the phase-space data storage requirement by a factor of 1000 and the accelerator simulation time by a factor of 10 or more. Agreement within 2% was achieved between the Monte Carlo calculations and measurements of the dose distributions in homogeneous and heterogeneous phantoms for various field sizes, source-surface distances, and beam modulations. The Monte Carlo calculated electron output factors were within 2% of the measured values for various treatment fields while the heterogeneity correction factors for various lung and bone phantoms were within 1% for photon beams and within 2% for electron beams. The EGS4/DOSXYZ Monte Carlo code was used for phantom and patient dose calculations. The results were compared to the dose distributions produced by a conventional treatment planning system and an intensity-modulated radiotherapy inverse-planning system. Significant differences (>5% in dose and >5 mm shift in isodose lines) were found between Monte Carlo calculations and the analytical calculations implemented in the commercial systems. Treatment sites showing the largest dose differences were for head and neck, lung, and breast cases. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00710-5].
引用
收藏
页码:2133 / 2143
页数:11
相关论文
共 48 条
[1]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS - AN EXTENSION OF THE 1983 AAPM PROTOCOL REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-39 [J].
ALMOND, PR ;
ATTIX, FH ;
HUMPHRIES, LJ ;
KUBO, H ;
NATH, R ;
GOETSCH, S ;
ROGERS, DWO .
MEDICAL PHYSICS, 1994, 21 (08) :1251-1260
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]  
[Anonymous], 1989, TISS SUBST RAD DOS M
[4]  
[Anonymous], 1994, P 11 ICCR MANCH UK
[5]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[6]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[7]  
BIELAJEW AF, 1987, USE COMPUTERS RAD TH, P65
[8]   Theoretical considerations of monitor unit calculations for intensity modulated beam treatment planning [J].
Boyer, A ;
Xing, L ;
Ma, CM ;
Curran, B ;
Hill, R ;
Kania, A ;
Bleier, A .
MEDICAL PHYSICS, 1999, 26 (02) :187-195
[9]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[10]  
CUNNINGHAM JR, 1995, PHYS CAN, V51, P190