An Event Window Based Load Monitoring Technique for Smart Meters

被引:119
作者
Dong, Ming [1 ]
Meira, Paulo C. M. [2 ]
Xu, Wilsun [1 ]
Freitas, Walmir [2 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2V4, Canada
[2] Univ Estadual Campinas, BR-13083852 Campinas, SP, Brazil
基金
加拿大自然科学与工程研究理事会;
关键词
Demand response; load management; load signatures; nonintrusive load monitoring; time-of-use price;
D O I
10.1109/TSG.2012.2185522
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The data collected by smart meters contain a lot of useful information. One potential use of the data is to track the energy consumptions and operating statuses of major home appliances. The results will enable homeowners to make sound decisions on how to save energy and how to participate in demand response programs. This paper presents a new method to breakdown the total power demand measured by a smart meter to those used by individual appliances. A unique feature of the proposed method is that it utilizes diverse signatures associated with the entire operating window of an appliance for identification. As a result, appliances with complicated middle process can be tracked. A novel appliance registration device and scheme is also proposed to automate the creation of appliance signature database and to eliminate the need of massive training before identification. The software and system have been developed and deployed to real houses in order to verify the proposed method.
引用
收藏
页码:787 / 796
页数:10
相关论文
共 17 条
[1]  
Amin SM, 2015, IEEE power and energy magazine, DOI [10.1109/MPAE.2005.1507024, 10.1109/MPAE.2005.150702]
[2]   Genetic algorithm for pattern detection in NIALM systems [J].
Baranski, M ;
Voss, A .
2004 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN & CYBERNETICS, VOLS 1-7, 2004, :3462-3468
[3]   TEMPERATURE CONTROL USING INTEGER-CYCLE BINARY RATE MODULATION OF THE AC MAINS [J].
BARRY, N ;
MCQUADE, E .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (05) :965-969
[4]   A BOTTOM-UP APPROACH TO RESIDENTIAL LOAD MODELING [J].
CAPASSO, A ;
GRATTIERI, W ;
LAMEDICA, R ;
PRUDENZI, A .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (02) :957-964
[5]  
Duan J, 2004, 2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 5, PROCEEDINGS, P988
[6]   NONINTRUSIVE APPLIANCE LOAD MONITORING [J].
HART, GW .
PROCEEDINGS OF THE IEEE, 1992, 80 (12) :1870-1891
[7]   A probabilistic model for residential consumer loads [J].
Heunis, SW ;
Herman, R .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (03) :621-625
[8]  
L. S. Communication, 2011, SMART GRID ELECT POW, P1, DOI [10.1002/9781119521129.ch15, DOI 10.1002/9781119521129.CH15]
[9]   Load Signature Study-Part I: Basic Concept, Structure, and Methodology [J].
Liang, Jian ;
Ng, Simon K. K. ;
Kendall, Gail ;
Cheng, John W. M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :551-560
[10]   Load Signature Study-Part II: Disaggregation Framework, Simulation, and Applications [J].
Liang, Jian ;
Ng, Simon K. K. ;
Kendall, Gail ;
Cheng, John W. M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :561-569