Pointwise assessment of three-dimensional computer reconstruction of mitral leaflet surfaces from rotationally scanned echocardiograms in vitro

被引:2
作者
Bashein, G
Legget, ME
Detmer, PR
机构
[1] Univ Washington, Dept Anesthesiol, Seattle, WA 98195 USA
[2] Green Lane Hosp, Auckland 3, New Zealand
[3] Philips Ultrasound, Bothell, WA USA
关键词
D O I
10.1016/j.echo.2003.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional transesophageal echocardiography offers promise for improved understanding of mitral leaflet pathology, but it has not been validated quantitatively, nor has the minimum number of imaging planes for satisfactory reconstruction been determined with a rotational scanning geometry. This study assessed its accuracy in vitro by comparing, on a 1 x 1-mm grid, the surfaces of mitral leaflets derived from 5-degree rotational ultrasonic scans with those derived from laser scans of casts of the atrial side of the leaflets. Overall, the ultrasonically derived surface had a mean absolute deviation of 0.65 +/- 0.12 min from the laser-derived surface. Using only alternate imaging planes (10-degree increments) made no significant difference in the overall distribution of deviations (P = .56), although the distributions on some individual specimens differed markedly. We conclude that 5-degree rotational scanning in vitro can reconstruct the mitral valve leaflets with sufficient accuracy and detail to render clinically important features.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 27 条
  • [1] Three-dimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects
    Acar, P
    Laskari, C
    Rhodes, J
    Pandian, N
    Warner, K
    Marx, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (05) : 745 - 749
  • [2] STRESSES IN THE CLOSED MITRAL-VALVE - A MODEL STUDY
    ARTS, T
    MEERBAUM, S
    RENEMAN, R
    CORDAY, E
    [J]. JOURNAL OF BIOMECHANICS, 1983, 16 (07) : 539 - &
  • [3] LEAST-SQUARES FITTING OF 2 3-D POINT SETS
    ARUN, KS
    HUANG, TS
    BLOSTEIN, SD
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) : 699 - 700
  • [4] Stereolithographic biomodeling to create tangible hard copies of cardiac structures from echocardiographic data - In vitro and in vivo validation
    Binder, TM
    Moertl, D
    Mundigler, G
    Rehak, G
    Franke, M
    Delle-Karth, G
    Mohl, W
    Baumgartner, H
    Maurer, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) : 230 - 237
  • [5] Three-dimensional echocardiographic planimetry of maximal regurgitant orifice area in myxomatous mitral regurgitation: Intraoperative comparison with proximal flow convergence
    Breburda, CS
    Griffin, BP
    Pu, M
    Rodriguez, L
    Cosgrove, DM
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (02) : 432 - 437
  • [6] Chauvel C, 2000, J HEART VALVE DIS, V9, P341
  • [7] Accurate assessment of mitral valve area in patients with mitral stenosis by three-dimensional echocardiography
    Chen, QW
    Nosir, YFM
    Vletter, WB
    Kint, PP
    Salustri, A
    Roelandt, JRTC
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (02) : 133 - 140
  • [8] De Castro S, 2002, J HEART VALVE DIS, V11, P173
  • [9] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [10] Mitral annulus distortion during beating heart surgery: A potential cause for hemodynamic disturbance - A three-dimensional echocardiography reconstruction study
    George, SJ
    Al-Ruzzeh, S
    Amrani, M
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (05) : 1424 - 1430