A within-subject comparison of adult patients using the nucleus F0F1F2 and F0F1F2B3B4B5 speech processing strategies

被引:11
作者
Parkinson, AJ
Tyler, RS
Woodworth, GG
Lowder, MW
Gantz, BJ
机构
[1] UNIV IOWA,DEPT OTOLARYNGOL HEAD & NECK SURG,IOWA CITY,IA
[2] UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
[3] UNIV IOWA,DEPT STAT & ACTUARIAL SCI,IOWA CITY,IA 52242
来源
JOURNAL OF SPEECH AND HEARING RESEARCH | 1996年 / 39卷 / 02期
关键词
cochlear implants; speech processing; feature extraction; deafness;
D O I
10.1044/jshr.3902.261
中图分类号
H [语言、文字];
学科分类号
05 ;
摘要
This study compares the Nucleus F0F1F2 and F0F1F2B3B4B5 (also known as ''Multipeak'' or ''Mpeak'') processing schemes in 17 patients wearing the Mini Speech Processor. All patients had at least 18 months implant experience using the F0F1F2 processing strategy. For this study, they were switched to the F0F1F2B3B4B5 processing strategy for 3 months. They then returned to using the F0F1F2 strategy for 3 months, then used the F0F1F2B3B4B5 strategy again for 3 months, and lastly used the F0F1F2 strategy for 3 months. Performance was evaluated with both schemes after each interval, using speech recognition tests and subjective ratings. Overall, differences between the results for the two processing schemes were not large. Average performance was somewhat better for the F0F1F2B3B4B5 strategy for word and sentence identification, but not for any of the other speech measures. Superior performance was observed in 8 patients with the F0F1F2B3B4B5 strategy. However, 6 of the 8 individuals were significantly better on only one of the six speech measures in the test battery. The other 2 patients performed better on two of the speech measures. Superior performance was also observed in 3 patients with the F0F1F2 strategy for consonant recognition. For the remaining patients, there was little difference in their performance with the two strategies. Information transmission analyses indicated that the F0F1F2B3B4B5 strategy transmitted consonant duration and frication cues more efficiently than F0F1F2. Experience with one strategy appeared to benefit performance with the other strategy.
引用
收藏
页码:261 / 277
页数:17
相关论文
共 30 条
[1]  
[Anonymous], 1983, Iowa cochlear implant tests
[2]  
Bench J., 1979, SPEECH HEARING TESTS
[3]   SURGICAL EVALUATION OF CANDIDATES FOR COCHLEAR IMPLANTS [J].
BLACK, FO ;
LILLY, DJ ;
FOWLER, LP ;
STYPULKOWSKI, PH .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01) :96-99
[4]   ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - DATA FROM HUMAN COCHLEAR IMPLANT USERS [J].
BROWN, CJ ;
ABBAS, PJ ;
GANTZ, B .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (03) :1385-1391
[5]  
*COCHL PTY LTD, 1989, NUCL AUD HDB MIN SYS, V22
[6]   PITCH SCALING AND SPEECH UNDERSTANDING BY PATIENTS WHO USE THE INERAID COCHLEAR IMPLANT [J].
DORMAN, MF ;
SMITH, L ;
MCCANDLESS, G ;
DUNNAVANT, G ;
PARKIN, J ;
DANKOWSKI, K .
EAR AND HEARING, 1990, 11 (04) :310-315
[7]  
GANTZ BJ, 1988, LARYNGOSCOPE, V98, P1100
[8]  
Hochmair-Desoyer I. J., 1985, COCHLEAR IMPLANTS, P291
[9]  
KIM HN, 1992, ANN OTO RHINOL LARYN, V101, P659
[10]   PSYCHOLOGICAL PREDICTORS OF AUDIOLOGICAL OUTCOMES OF MULTICHANNEL COCHLEAR IMPLANTS - PRELIMINARY FINDINGS [J].
KNUTSON, JF ;
HINRICHS, JV ;
TYLER, RS ;
GANTZ, BJ ;
SCHARTZ, HA ;
WOODWORTH, G .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (10) :817-822