Determination of gas phase peroxyacetic acid using pre-column derivatization with organic sulfide reagents and liquid chromatography

被引:29
作者
Effkemann, S
Brodsgaard, S
Mortensen, P
Linde, SA
Karst, U
机构
[1] Univ Munster, Inst Anorgan Chem, Abt Analyt Chem, D-48149 Munster, Germany
[2] Dansk Miljo Ctr AS, Miljo Kemi, DK-8464 Galten, Denmark
关键词
derivatization; LC; peroxyacetic acid; amino(methylsulfanyl)phenyldiazenylphenylsulfonylethanol; methyltolyl sulfide; peroxides;
D O I
10.1016/S0021-9673(99)00734-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The first selective HPLC methods for the determination of peroxyacetic acid (PAA) in gas phase samples have been developed. PAA reacts with 2-([3-{2-[4-amino-2-(methylsulfanyl)phenyl]-1-diazenyl}phenyl]sulfonyl)-1-ethanol (ADS) to form the corresponding sulfoxide. Sampling may be performed in impingers using aqueous solutions of the reagent or by test tubes with the reagent coated on a solid sorbent. Sulfide and sulfoxide are separated by means of HPLC and detected at a wavelength of 410 nm. The method is highly selective for PAA in the presence of hydrogen peroxide when sampling in impingers. A 10 000-fold excess of hydrogen peroxide leads to the same peak area compared to PAA. Limit of detection is 10(-8) mol PAA, thus corresponding to PAA concentration of 46 ppb when using a sampling time of 10 min with a flow-rate at 500 ml/min. Another sulfide reagent, methyl-p-tolyl sulfide (MTS) has been used in a similar way with impinger sampling. Major advantages of ADS towards MTS are improved UV-Vis spectroscopic properties and reduced volatility. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:551 / 561
页数:11
相关论文
共 27 条
[1]   QUANTITATIVE-DETERMINATION OF ORGANIC PEROXIDES [J].
BAJ, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (03) :159-161
[2]  
*BER CHEM, 1980, MERKBL ORG PER
[3]  
BIRCH BJ, 1989, Patent No. 0333246
[4]  
BOULLION G, 1983, CHEM FUNCTIONAL GROU, P287
[5]   DETERMINATION OF ORGANIC PEROXYACIDS AND HYDROPEROXIDES BY GAS-CHROMATOGRAPHY [J].
CAIRNS, GT ;
RUIZDIAZ, R ;
SELBY, K ;
WADDINGTON, DJ .
JOURNAL OF CHROMATOGRAPHY, 1975, 103 (02) :381-384
[6]  
CHRISTNER JE, 1992, Patent No. 22806
[7]  
DANS J, 1912, CHEM BER, V45, P1845
[8]   DETERMINATION OF PERACIDS IN THE PRESENCE OF A LARGE EXCESS OF HYDROGEN-PEROXIDE USING A RAPID AND CONVENIENT SPECTROPHOTOMETRIC METHOD [J].
DAVIES, DM ;
DEARY, ME .
ANALYST, 1988, 113 (09) :1477-1479
[9]   GAS-LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF PERACIDS IN THE PRESENCE OF A LARGE EXCESS OF HYDROGEN-PEROXIDE [J].
DIFURIA, F ;
PRATO, M ;
QUINTILY, U ;
SALVAGNO, S ;
SCORRANO, G .
ANALYST, 1984, 109 (08) :985-987
[10]   Liquid chromatographic simultaneous determination of peroxycarboxylic acids using postcolumn derivatization [J].
Effkemann, S ;
Pinkernell, U ;
Neumüller, R ;
Schwan, F ;
Engelhardt, H ;
Karst, U .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3857-3862