Modeling of the wind turbine with a doubly fed induction generator for grid integration studies

被引:430
作者
Lei, YZ [1 ]
Mullane, A [1 ]
Lightbody, G [1 ]
Yacamini, R [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Elect & Elect Engn, Cork, Ireland
关键词
induction generators; power system transient stability; reactive power control; variable speed drives; wind power generation;
D O I
10.1109/TEC.2005.847958
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to its many advantages such as the improved power quality, high energy efficiency and controllability, etc. the variable speed wind turbine using a doubly fed induction generator (DFIG) is becoming a popular concept and thus the modeling of the DFIG based wind turbine becomes an interesting research topic. Fundamental frequency models have been presented but these models are often complex with significant numerical overhead as the power converter block consisting of power control, rotor side and grid side converter control and DC link are often simulated in detail. This paper develops a simple DFIG wind turbine model in which the power converter is simulated as a controlled voltage source, regulating the rotor current to meet the command of real and reactive power production. This model has the form of traditional generator model and hence is easy to integrate into the power system simulation tool such as PSS/E. As an example, the interaction between the Arklow Bank Wind Farm and the Irish National Grid was simulated using the proposed model. The model performance and accuracy was also compared with the detailed model developed by DIgSILENT. Considering the simplification adopted for, the model development, the limitation and applicability of the model were also discussed in this paper.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 20 条
[1]  
AKHMATOV V, 2003, THESIS TU DENMARK LY
[2]  
[Anonymous], 2002, NRELTP50029415
[3]   DOUBLE-OUTPUT INDUCTION GENERATOR OPERATING AT SUBSYNCHRONOUS AND SUPERSYNCHRONOUS SPEEDS - STEADY-STATE PERFORMANCE OPTIMIZATION AND WIND-ENERGY RECOVERY [J].
CADIRCI, I ;
ERMIS, M .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1992, 139 (05) :429-442
[4]  
CARLIN PW, 2001, NRELTP50028607
[5]   Grid power quality with variable speed wind turbines [J].
Chen, Z ;
Spooner, E .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2001, 16 (02) :148-154
[6]  
*DIGSILENT GMBH, 2003, DYN MOD DOUBL FED IN
[7]   NEW SLIP POWER RECOVERY SCHEME WITH IMPROVED SUPPLY POWER FACTOR. [J].
Doradla, Seshagiri R. ;
Chakravorty, Sudarshan ;
Hole, Kashinath E. .
IEEE Transactions on Power Electronics, 1988, 3 (02) :200-207
[8]   A third order model for the doubly-fed induction machine [J].
Feijóo, A ;
Cidrás, J ;
Carrillo, C .
ELECTRIC POWER SYSTEMS RESEARCH, 2000, 56 (02) :121-127
[9]  
HANSEN AD, 2003, RISOR400EN RIS NAT L
[10]   CYCLOCONVERTOR-EXCITED DIVIDED-WINDING DOUBLY-FED MACHINE AS A WIND-POWER CONVERTER [J].
HOLMES, PG ;
ELSONBATY, NA .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1984, 131 (02) :61-69