Comparison of exhaled nitric oxide measurements between NIOX MINO® electrochemical and Ecomedics chemiluminescence analyzer

被引:48
作者
Boot, J. D. [1 ]
de Ridder, L. [1 ]
de Kam, M. L. [1 ]
Calderon, C. [2 ]
Mascelli, M. A. [2 ]
Diamant, Z. [1 ]
机构
[1] Ctr Human Drug Res, NL-2333 CL Leiden, Netherlands
[2] Centocor Inc, Malvern, PA 19355 USA
关键词
Airway inflammation; Exhaled NO; NIOX MINO (R); Ecomedics; Reproducibility;
D O I
10.1016/j.rmed.2008.06.021
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: Exhaled nitric oxide (eNO) is an established, noninvasive biomarker of active airway inflammation in (atopic) asthma. Treatment with anti-inflammatory therapy, such as inhaled corticosteroids, effectively decreases eNO levels. The NIOX MINO (R) (MINO) is a hand-held, relatively inexpensive, electrochemical device that has been shown to yield comparable eNO measurements to the NIOX stationary unit. Aim: To compare measurements of MINO with another widely used and validated stationary chemiluminescence analyzer, the Ecomedics (ECO). Methods: We performed subsequent eNO measurements on ECO and MINO in 50 subjects (19 healthy volunteers, 18 healthy smokers and 13 non-smoking, atopic asthmatics, not on controller therapy) on two visits 4-10 days apart. The mean of three acceptable measurements by ECO and the first acceptable measurement with the MINO were used for analysis. Results: Both devices yielded reproducible eNO values for all subjects on both visits, with an overall CV of 22.7% (ECO) and 18.3% (MINO). A significant correlation was found between both devices (r = 0.97, p < 0.0001). Bland-Altman plots showed a high degree of agreement for the entire study population (mean difference MINO vs ECO = -10%; 95% limit of agreement were -36% and +28%) and in the three individual subgroups. Conclusions: Exhaled NO values measured with the MINO are reproducible and in agreement with the ECO. Our results add further evidence to the reliability of the MINO and warrant its applicability in research and clinical practice. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1667 / 1671
页数:5
相关论文
共 15 条
[1]
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children [J].
Alving, K ;
Janson, C ;
Nordvall, L .
RESPIRATORY RESEARCH, 2006, 7 (1)
[2]
ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005 [J].
American Thoracic Society ;
European Respiratory Society .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (08) :912-930
[3]
[Anonymous], 2016, Global strategy for asthma management and prevention
[4]
Economic evaluation of FENO measurement in diagnosis and 1-year management of asthma in Germany [J].
Berg, Jenny ;
Lindgren, Peter .
RESPIRATORY MEDICINE, 2008, 102 (02) :219-231
[5]
A critical appraisal of methods used in early clinical development of novel drugs for the treatment of asthma [J].
Boot, J. D. ;
Panzner, P. ;
Diamant, Z. .
PULMONARY PHARMACOLOGY & THERAPEUTICS, 2007, 20 (03) :201-219
[6]
A comparison of exhaled nitric oxide measurements performed using three different analysers [J].
Borrill, Zoe ;
Clough, David ;
Truman, Nick ;
Morris, Julie ;
Langley, Stephen ;
Singh, Dave .
RESPIRATORY MEDICINE, 2006, 100 (08) :1392-1396
[7]
Reliability of a new hand-held device for the measurement of exhaled nitric oxide [J].
Khalili, B. ;
Boggs, P. B. ;
Bahna, S. L. .
ALLERGY, 2007, 62 (10) :1171-1174
[8]
Validation of a hand-held exhaled nitric oxide analyzer for use in children [J].
McGill, Claire ;
Malik, Gulshan ;
Turner, Stephen W. .
PEDIATRIC PULMONOLOGY, 2006, 41 (11) :1053-1057
[9]
Portable exhaled nitric oxide measurement - Comparison with the "gold standard" technique [J].
Menzies, Daniel ;
Nair, Arun ;
Lipworth, Brian J. .
CHEST, 2007, 131 (02) :410-414
[10]
Standardisation of spirometry [J].
Miller, MR ;
Hankinson, J ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Crapo, R ;
Enright, P ;
van der Grinten, CPM ;
Gustafsson, P ;
Jensen, R ;
Johnson, DC ;
MacIntyre, N ;
McKay, R ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Viegi, G ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :319-338